𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Drop size and holdup in a reciprocating plate extraction column

✍ Scribed by M.H.I. Baird; S.J. Lane


Publisher
Elsevier Science
Year
1973
Tongue
English
Weight
860 KB
Volume
28
Category
Article
ISSN
0009-2509

No coin nor oath required. For personal study only.

✦ Synopsis


This paper reports measurements of droplet sizes and holdup in liquid-liquid systems in a 2 in. dia. reciprocating plate extraction column, in the absence of mass transfer.

The Sauter mean droplet diameter was found to depend on the product of plate amplitude and frequency and on the system properties, but it was not in general affected by the throughput. It could be correlated fairly well using a turbulent dispersion model similar to that which has been applied successfully to dispersions in stirred tanks.

A simple hydrodynamic model is proposed for the holdup, assuming the droplet diameter to depend on turbulent energy dissipation. This model is consistent with the experimental data if it is assumed that droplets in kerosene undergo hindered circulation while droplets in methyl isobutyl ketone circulate freely. The model also agrees with some previously published data on holdup in a gas-liquid system in a pulsed column, assuming that the gas bubbles circulate freely.


πŸ“œ SIMILAR VOLUMES


Drop size distribution and holdup profil
✍ C. Tsouris; V. I. Kirou; L. L. Tavlarides; C. Y. Wang πŸ“‚ Article πŸ“… 1994 πŸ› American Institute of Chemical Engineers 🌐 English βš– 979 KB

A population-balance-equation model is employed for the analysis of liquid-liquid extraction columns. This model considers drop breakage, coalescence, and exit phenomena for the drop phase caused by drop-drop and drop-continuous phase interactions. Drop breakage and coalescence rates are employed fr

Drop size distributions and holdups in a
✍ K. Miyanami; K. Tojo; T. Yano; K. Miyaji; I. Minami πŸ“‚ Article πŸ“… 1975 πŸ› Elsevier Science 🌐 English βš– 485 KB

## Drop size distributions and dispersed phase holdups in a multistage vibrating disk column (MVDC) have been investigated. The drop sizes and holdups are strongly affected by the wave-form of disk vibration. The drop size distributions, mean diameters and holdups are well correlated in terms of

Calculation of the drop size in pulsed s
✍ W. Pietzsch; T.H. Pilhofer πŸ“‚ Article πŸ“… 1984 πŸ› Elsevier Science 🌐 English βš– 440 KB

## Abstrae-A new method for the calculation of drop sizes in pulsed sieve-plate extraction columns is reported. Under certain assumptions for the motion df the drops in the vicinity of the plates, it is possible to develop an equation that is confirmed by measurements in a much greater range, espe