This paper reports measurements of droplet sizes and holdup in liquid-liquid systems in a 2 in. dia. reciprocating plate extraction column, in the absence of mass transfer. The Sauter mean droplet diameter was found to depend on the product of plate amplitude and frequency and on the system propert
Calculation of the drop size in pulsed sieve-plate extraction columns
โ Scribed by W. Pietzsch; T.H. Pilhofer
- Publisher
- Elsevier Science
- Year
- 1984
- Tongue
- English
- Weight
- 440 KB
- Volume
- 39
- Category
- Article
- ISSN
- 0009-2509
No coin nor oath required. For personal study only.
โฆ Synopsis
Abstrae-A
new method for the calculation of drop sizes in pulsed sieve-plate extraction columns is reported. Under certain assumptions for the motion df the drops in the vicinity of the plates, it is possible to develop an equation that is confirmed by measurements in a much greater range, especially of the pulsation intensity, than other equations being known up to now. Additionally, a dependence of the drop diameter on the hole diameter at constant fractional free area results from that new equation, which has been proven so far only experimentally. Finally, with the developed equation under consideration of the time-dependent variations of the effective forces it is possible to make qualitative predictions on the type of the drop size distribution to be expected.