𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Discontinuous electrolyte systems for improved detection of biologically active amines and acids by capillary electrophoresis with laser-induced native fluorescence detection

✍ Scribed by Ming-Mu Hsieh; Huan-Tsung Chang


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
383 KB
Volume
26
Category
Article
ISSN
0173-0835

No coin nor oath required. For personal study only.

✦ Synopsis


Discontinuous electrolyte systems for improved detection of biologically active amines and acids by capillary electrophoresis with laser-induced native fluorescence detection

On-line concentration and separation of biologically active amines and acids by capillary electrophoresis (CE) in conjunction with laser-induced fluorescence using an Nd:YAG laser at 266 nm under discontinuous conditions is presented. The suitable conditions for simultaneous analysis of amines and acids were: samples were prepared in a solution (pH* 3.1) consisting of 10 mM citric acid, 89% acetonitrile (ACN), and water; a capillary was filled with 1.5 M Tris-borate (TB) buffer (pH 10.0); and the anodic vial contained PTG10 buffer (pH* 9.0) that consists of 50 mM propanoic acid, Tris, 10% glycerol, and water. After injecting a large-volume sample, amines and acids were separately stacked at the front (cathodic side) and back (anodic side) of the acidic sample zone, mainly because of changes in their electrophoretic mobilities as a result of changes in pH, viscosity, and electric field when high voltage was applied. When the sample was injected at 15 kV for 360 s, the concentration limits of detection (LODs) for 5-hydroxytryptamine (5-HT) and 5-hydroxyindole-3-acetic acid (5-HIAA) were 0.27 and 0.31 nM, respectively, which are about 400-and 800-fold sensitivity improvements when compared to those injected at 1 kV for 10 s. For the analysis of amines, samples were prepared in 100 mM citric acid (pH* 1.8) containing 89% ACN and both the capillary and anodic vial were filled with 400 mM PTG20 (propanoic acid, Tris, 20% glycerol, and water) at pH* 4.5. Using a large injection volume (15 kV for 360 s), we achieved concentration LODs of 17 pM and 0.3 nM for tryptamine and epinephrine, which are about 5200-and 14 000-fold sensitivity improvements, respectively, in comparison with those injected at 1 kV for 10 s. The features of simplicity (no sample pretreatment), rapidity (12 min), and sensitivity for identification of amines and acids of interest in urine samples show diagnostic potential of the two approaches developed in this study.


πŸ“œ SIMILAR VOLUMES


Noncovalent labeling of myoglobin for ca
✍ Ebbing P. de Jong; Jeremy E. Melanson; Charles A. Lucy πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 142 KB πŸ‘ 2 views

## Abstract Traditional protein labeling reactions for capillary electrophoresis (CE) with laser‐induced fluorescence (LIF) detection suffer from a variety of disadvantages. The reactions can be nonquantitative on a reasonable time scale, require relatively high concentrations of protein and fluoro