Direct injection versus liquid-liquid extraction for post-dose human plasma sample analysis by high performance liquid chromatography with tandem mass spectrometry (LC/MS/MS) have been studied using a drug candidate compound. For the direct-injection method, an Oasis 1 HLB column (1 Γ 50 mm, 30 mm)
Direct injection of plasma to determine pseudoephedrine by high performance liquid chromatography with column switching
β Scribed by Ping Guo; Zhangwan Li; Twuen Li; Xiaomin Wang; Famei Li
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 52 KB
- Volume
- 13
- Category
- Article
- ISSN
- 0269-3879
No coin nor oath required. For personal study only.
β¦ Synopsis
An HPLC method has been developed for the determination of pseudoephedrine in plasma using column switching. Preparation of the sample was simple in that only 1000 mL of water was added to 200 mL of plasma before injection. A 900 mL aliquot was injected onto the precolumn. Double distilled water was used to elute and remove proteins and polar components in the sample. The components retained on the precolumn were flushed forward onto the analytical column by the mobile phase (acetonitrile-0.2 mol/L ammonium sulphate, 10:90 v/v) with automated column switching. The limit of determination of pseudoephedrine in plasma was 12 ng/mL. The relative standard deviations of intra-and inter-assay for the determination of pseudoephedrine in plasma were 1.2-9.8% over the concentration range 1020-21.8 ng/mL. The mean recovery by on-line solid phase extraction was 94.76% (RSD = 1.1%).
π SIMILAR VOLUMES
A sensitive high-performance liquid chromatographic (HPLC) method for the quantitation of the morphine 3-esters 1[3-(2,2-dimethylvaleroyl)-morphine (A), 3-(2-phenylbenzoyl)-morphine (B) and 3-(2,2-diphenylpropionyl)-morphine (C)] in rabbit plasma is described. Sample preparation was based on reverse
A coupled liquid chromatography/tandem mass spectrometry assay was developed for simultaneous determination of Ro 48-6791 and its secondary amine metabolite in human plasma samples with a quantification limit for both compounds of 1 pg/mL using a 1 mL plasma aliquot. The method exploits the enhanced
A method was developed for the bio-analysis of Ecteinascidin 743 (ET-743) using miniaturized liquid chromatography (LC) coupled to an electrospray ionization sample inlet (TurbolonSpray) and two quadrupole mass analyzers (LC/ESI-MS/MS). Solid-phase extraction was used as a sample pretreatment proced
A high-performance liquid chromatographic system, combining solid-phase extraction and automated precolumn derivatization is described for the routine determination of methotrexate in human plasma. The sample extraction and elution onto the analytical column were performed automatically and concomit
A liquid chromatographic atmospheric pressure chemical ionization tandem mass spectrometric method is described for the determination of 21-hydroxydeflazacort in human plasma using dexamethasone 21-acetate as an internal standard. The procedure requires a single diethyl ether extraction. After evapo