Digital position determination system for electron microscopy
โ Scribed by Martin F. Hohmann-Marriott; William P. Sharp; Robert W. Roberson; Robert E. Blankenship
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 130 KB
- Volume
- 67
- Category
- Article
- ISSN
- 1059-910X
No coin nor oath required. For personal study only.
โฆ Synopsis
The precise determination of object positions within a specimen grid is important for many applications in electron microscopy. For example, real-time position determination is necessary for current statistical approaches and the efficient mapping and relocation of objects. Unfortunately, precise real-time position determination is not available on many older electron microscopes with manual stage controls. This report demonstrates the cost-effective and flexible implementation of a digital position determination system that can be adapted to many hand-operated electron microscopes. A customized solution that includes the hardware and software to accomplish position determination is presented. Lists of required parts, instructions for building the hardware, and descriptions of the developed programs are included. Two LED-photodiode assemblies detect x and y movements via an optical wheel that is in physical contact with the mechanical x and y stage control elements. These detector assemblies are interfaced with an integrated circuit that converts movement information into serial port-compatible signals, which are interpreted by a computer with specialized software. Two electron microscopes, a Philips CM12 (S)TEM and a Philips 201 TEM, were equipped with the described digital position determination system. The position fidelity and position fidelity after reloading of grids were determined for both microscopes. The determined position deviation was 1.06 microm in the x axis and 0.565 microm in the y axis for the Philips CM12 (S)TEM, and 0.303 microm in the x axis and 0.545 microm in the y axis for the Philips 201 TEM. After reloading and computational realigning, the determined average position variation was 2.66 microm in the x axis and 2.61 microm in the y axis for the Philips CM12 (S)TEM, and 1.13 microm in the x axis and 1.27 microm in the y axis for the Philips 201 TEM.
๐ SIMILAR VOLUMES
A new setup for freeze-substitution and a versatile controlling system has been developed. Our goal was to build a simple system allowing precise control of the physical parameters of freeze-substitution experiments to learn more about their influences on the cellular ultrastructure and immunoreacti
This study examines the feasibility of combining computer image digitization, image enhancement, and point counting stereological techniques to quantify video images from transmission electron microscopes (TEM). The essential hardware consists of an IBM PC/AT, a Matrox imaging board, a digitizing ta