## Abstract ## Purpose To compare the diagnostic accuracy of contrast‐enhanced ultrasonography (CE‐US), contrast‐enhanced CT (CE‐CT), and superparamagnetic iron oxide‐enhanced MRI (SPIO‐MRI) with diffusion‐weighted imaging (DWI) in the evaluation of colorectal hepatic metastases. ## Materials and
Diagnosis of colorectal hepatic metastases: Comparison of contrast-enhanced CT, contrast-enhanced US, superparamagnetic iron oxide-enhanced MRI, and gadoxetic acid-enhanced MRI
✍ Scribed by Ali Muhi; Tomoaki Ichikawa; Utaroh Motosugi; Hironobu Sou; Hiroto Nakajima; Katsuhiro Sano; Mika Sano; Satoshi Kato; Takatoshi Kitamura; Zareen Fatima; Kimiyo Fukushima; Hiroshi Iino; Yoshiyuki Mori; Hideki Fujii; Tsutomu Araki
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 513 KB
- Volume
- 34
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose:
To compare the diagnostic accuracy of contrast‐enhanced computed tomography (CE‐CT), contrast‐enhanced ultrasonography (CE‐US), superparamagnetic iron oxide‐enhanced magnetic resonance imaging (SPIO‐MRI), and gadoxetic acid‐enhanced MRI (Gd‐EOB‐MRI) in the evaluation of colorectal hepatic metastases.
Materials and Methods:
In all, 111 patients with colorectal cancers were enrolled in this study. Of the 112 metastases identified in 46 patients, 31 in 18 patients were confirmed histologically and the remaining 81 in 28 patients were confirmed by follow‐up imaging. CE‐CT, CE‐US, SPIO‐MRI, and Gd‐EOB‐MRI were evaluated. Mean (of three readers, except for CE‐US) area under the receiver operating characteristic curve (A~z~), sensitivities, and positive predictive values (PPV) were calculated. Each value was compared to the others by variance z‐test or chi‐square test with Bonferroni correction.
Results:
For all lesions, mean A~z~ and sensitivity of Gd‐EOB‐MRI (0.992, 95% [56/59]) were significantly greater than those of CE‐CT (0.847, 63% [71/112]) and CE‐US (0.844, 73% [77/106]). For lesions ≤1 cm, mean A~z~ and sensitivity of Gd‐EOB‐MRI (0.999, 92% [22/24]) were significantly greater than those of CE‐CT (0.685, 26% [13/50]) and CE‐US (0.7, 41% [18/44]). Mean A~z~ (95% CI) of SPIO‐MRI for all lesions (0.966 [0.929–0.987]) and lesions ≤ 1 cm (0.961 [0.911–0.988]) were significantly greater than those of CE‐CT and CE‐US. Mean sensitivity of SPIO‐MRI for lesions ≤1 cm (63%, 26/41) was significantly greater than that of CE‐CT.
Conclusion:
Gd‐EOB‐MRI and SPIO‐MRI were more accurate than CE‐CT and CE‐US for evaluation of liver metastasis in patients with colorectal carcinoma. J. Magn. Reson. Imaging 2011;. © 2011 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Dynamic contrast‐enhanced MRI (DCE‐MRI) is frequently used to provide response biomarkers in clinical trials of novel cancer therapeutics but assessment of their physiological accuracy is difficult. DCE‐CT provides an independent probe of similar pharmacokinetic processes and may be mod
## Abstract A major challenge for cellular and molecular MRI is to study interactions between two different cell populations or biological processes. We studied the possibility to simultaneously image contrast agents based on two different MRI contrast mechanisms: chemical exchange saturation trans
## Abstract Cervical tumors of 38 cervix cancer patients were scanned by __T__~1~‐weighted dynamic contrast enhanced (DCE) MRI and then by DCE‐CT on the same day. Gadodiamide and iohexol were respectively used as the low‐molecular‐weight contrast agent in DCE‐MRI and DCE‐CT. Under an extended Tofts
## Abstract ## Purpose: To compare enhancement of liver parenchyma in MR imaging after injection of hepatocyte‐specific contrast media. ## Materials and Methods: Patients (n = 295) with known/suspected focal liver lesions randomly received 0.025 mmol gadoxetic acid/kg body weight or 0.05 mmol ga
## Abstract ## Purpose To study the recognition of malignant lesions of the liver on diffusion‐weighted images (DWI) can be improved by the administration of superparamagnetic iron oxide (SPIO). ## Materials and Methods Pre‐ and post‐SPIO mediated DWI of the liver was compared in six patients wi