𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Development of thermoplastic polyurethane vascular prostheses

✍ Scribed by Yun Kyung Kang; Chung Hee Park; Hak Chang; Kyungwon Minn; Chan Young Park


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
397 KB
Volume
110
Category
Article
ISSN
0021-8995

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

In this study, the optimum electrospinning conditions for a thermoplastic polyurethane/N,N‐dimethylformamide solution were sought. Under these conditions, polyurethane tubes for artificial blood vessels were produced via electrospinning, and various properties of the specimen were measured. The optimum electrospinning conditions were a concentration of 16 wt %, a voltage of 13.0 kV, and a tip‐to‐collector distance of 15 cm at 27Β°C and 80% relative humidity. The thermal behavior from a differential scanning calorimeter showed that this polyurethane web was thermally stable in the body temperature range. Enzyme hydrolysis of the web revealed that the polyurethane vascular prostheses would perform as nondegradable blood vessels in the body system. The pore size range of the electrospun polyurethane vascular prostheses was 0–3.5 ΞΌm. With a tensile stress of about 8–9 MPa and a tensile strain of about 80%, the tensile properties were expected to be superior to those of existing vascular prostheses made of polyester and expanded polytetrafluoroethylene. In the last stage, heparin and collagen were treated on the surfaces of artificial vessels to reduce the probability of thrombi forming during the initial stage of grafting, and so the treated specimens exhibited a lower possibility of thrombi forming than untreated ones in a blood coagulation test. Β© 2008 Wiley Periodicals, Inc. J Appl Polym Sci, 2008


πŸ“œ SIMILAR VOLUMES


A new generation of polyurethane vascula
✍ Eberhart, Andreas ;Zhang, Ze ;Guidoin, Robert ;Laroche, GaοΏ½tan ;Guay, Louis ;De πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 272 KB

Three polyurethane (PU) vascular grafts with novel designs were investigated and compared in terms of the microporous structure, reinforcement technology, polymer chemistry, microphase separation, and mechanical properties. The Corvita graft, composed of a poly(carbonate urethane) polymer, displayed

Ultrasonic detection of segmental relaxa
✍ A. W. Aziz; S. N. Lawandy πŸ“‚ Article πŸ“… 1986 πŸ› John Wiley and Sons 🌐 English βš– 402 KB πŸ‘ 1 views

The change in attenuation of longitudinal waves has been measured as a function of frequency and temperature for thermoplastic polyurethanes of different hardness covering a range from rubbery hardness to plastic. Analysis of the results show some segmental relaxations and the activation energies we