𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Development of a coupled liquid chromatography-isotope dilution inductively coupled plasma mass spectrometry method for lead speciation

✍ Scribed by Alistair A. Brown; Les Ebdon; Steve J. Hill


Publisher
Elsevier Science
Year
1994
Tongue
English
Weight
833 KB
Volume
286
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


A method has been developed for lead speciation using liquid chromatography with isotope dilution inductively coupled plasma mass spcctrometry W-ID-ICP-MS).

Inorganic lead (Pb*+), trimethyllead (Me,Pb+) and triethyllead (EtsPb+) were separated on a S-pm Hypersil ODS column using a programmed gradient of 10: 90 to 30: 70 methanol-buffer eluent. The buffer was prepared by mixing equal amounts of 0.1 mol 1-l sodium acetate and acetic acid each containing 4 mm01 1-l sodium pentanesulfonic acid. To minimise the dead volume of the interface a single pass 40 ml volume spray chamber with a concentric glass nebuliser was used to coupled the LC and ICP-MS. Best precision isotope ratio measurements were obtained with peak jumping and short dwell times (SO ps). The overall detection limit (3~) for trimethyllead ions was 0.48 ng g-' as lead.


📜 SIMILAR VOLUMES


Determination of germanium by isotope di
✍ Richard A. Mortlock; Philip.N. Froelich 📂 Article 📅 1996 🏛 Elsevier Science 🌐 English ⚖ 671 KB

Inorganic germanium in aqueous solution is determined by a combination of isotope dilution, hydride generation, and inductively-coupled plasma mass spectrometxy (ID-HG-ICP-MS). Samples (5-20ml) are spiked with an enriched stable isotope ("Ge). Germanic acid is reduced by sodium borohydride to german

Isotope dilution inductively coupled pla
✍ Christian Pin; Sylvie Lacombe; Philippe Telouk; Jean-Louis Imbert 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 781 KB

The potential of Isotope ddutlon mductwely coupled plasma mass spectrometry (ICP-MS) was evaluated for the determmatlon of trace amounts of uramum and thormm m sdlcate rocks Compared with conventlonal Isotope ddutlon methods usmg thermal lomzatlon mass spectrometers, the major benefit IS a large Inc

Comparison of different derivatization a
✍ Garc�a Fern�ndez, Rub�n; Montes Bay�n, Mar�a; Garc�a Alonso, J. Ignacio; Sanz-Me 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 108 KB 👁 2 views

A novel interface design for coupling gas chromatography and inductively coupled plasma mass spectrometry (GC/ICP-MS) was used to perform mercury speciation in biological tissues. Three derivatization approaches were optimized and compared for this purpose: anhydrous butylation using a Grignard reag

Determination of traces of copper, cadmi
✍ Pei-Ling Lu; Kuang-Shie Huang; Shiuh-Jen Jiang 📂 Article 📅 1993 🏛 Elsevier Science 🌐 English ⚖ 620 KB

Plow-injection isotope dilution inductively coupled plasma mass spcctrometry (RIP-MS) was applied to the determination of Cu, Cd and Pb in several biological and environmental reference materials. The isotope ratios for each injection were calculated from the areas of the flow-jnjection peaks. The p