Street cocaine varies in purity and is often adulterated with various compounds. Some of these additives, such as lidocaine, may increase the toxicity of cocaine. A new precise, accurate and sensitive reversedphase high-performance liquid chromatography method for the determination of cocaine, its m
Development and validation of a method for the analysis of cafenstrole and its metabolite in brown rice grains and rice straw using high-performance liquid chromatography
β Scribed by A. M. Abd El-Aty; Go-Woon Lee; M. I. R. Mamun; Jeong-Heui Choi; Soon-Kil Cho; Ho-Chul Shin; Jae-Han Shim
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 747 KB
- Volume
- 22
- Category
- Article
- ISSN
- 0269-3879
- DOI
- 10.1002/bmc.934
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
The present work reports the extraction and cleanβup procedures, as well as the chromatographic conditions developed, for the determination of cafenstrole and its metabolite (CHMβ03) residues in brown rice grains and rice straw using HPLCβUV detection. The method makes use of an Apollo C~18~ column and acetonitrile : water : acetic acid as a mobile phase for both cafenstrole and its metabolite in rice and rice straw. Using these conditions cafenstrole and its metabolite were resolved with a retention time (R~t~) of less than 14 min. The analytes were confirmed using positive atmospheric pressure ionization LCβMS with selected ion monitoring. The average recoveries of cafenstrole were found to be 87.0β92.5 and 87.6β88.3%. However, they ranged from 81.5 to 81.6% and from 76.1 to 78.5% for cafenstrole metabolite (CHMβ03), in rice grains and rice straw, respectively, with relative standard deviations ranging from 1.4 to 6.6%. The limits of detection (LODs) of both cafenstrole and its metabolite were 0.002 and 0.02 ppm and 0.025 and 0.04 ppm, respectively. Field trials with recommended or double the recommended dose revealed that the herbicide could safely be recommended for application in rice and rice straw as no residues were detected in the harvest samples. Copyright Β© 2007 John Wiley & Sons, Ltd.
π SIMILAR VOLUMES
## Abstract Cocaine abuse is an extensive problem in the USA. During the past decade, ketamine abuse also has emerged as a public health concern and is now considered a controlled substance. The prevalence of the simultaneous use of cocaine and ketamine has been shown to be high. Previous research
The objective was to develop a simple HPLC method to quantify exenatide-a 39 amino acid residue incretin mimetic used in diabetes therapy. To date, only non-validated, sometimes incomplete, gradient methods have been reported in the literature. Isocratic separation was achieved using a C4 column and
## Abstract A simple and reproducible HPLC method permitting simultaneous determination of phenolic acids (gallic, vanillic, syringic, and ferulic), phenolic aldehydes (vanillin, syringaldehyde, coniferaldehyde, and sinapaldehyde), and furanic derivatives (furfural, 5βhydroxymethylfurfural, and 5βm
A rapid, simple and reliable high-performance liquid chromatography (HPLC) column-switching method with UV detection (270 nm) for the simultaneous determination of propentofylline and its metabolites in human and rat sera was developed. The method involves direct injection of serum onto an HPLC colu