Development and validation of a chiral capillary electrophoresis method for assay and enantiomeric purity control of pramipexole
✍ Scribed by Xiaolan Deng; Xin Hai; Ruud Vervoort; Dirk Pamperin; Erwin Adams; Ann Van Schepdael
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 152 KB
- Volume
- 34
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A rapid method for the enantioseparation of pramipexole and its R‐enantiomer has been developed by capillary electrophoresis. The influence of chemical and instrumental parameters was investigated including the type and concentration of chiral selectors, buffer composition and pH, co‐ions, applied voltage, capillary length and temperature. Optimal separation conditions were obtained using a 50 mM phosphate buffer (pH 2.8) containing 25 mM carboxymethyl‐β‐cyclodextrin on a fused‐silica capillary. Online UV detection was performed at 262 nm. A voltage of 25 kV was applied, and the capillary temperature was kept at 25°C. Hydrodynamic injection was performed at 3.45 kPa for 5.0 s. The separation of enantiomers was achieved in <6.5 min. The method was further validated in terms of stability of solutions, selectivity, linearity (both pramipexole and R‐enantiomer, R^2^>0.995), LOD and LOQ (0.91 and 2.94 μg/mL, respectively), repeatability (RSD<1.5%) and accuracy (pramipexole, 100.4%; R‐enantiomer, 100.5%). The proposed method was then applied to two kinds of pramipexole dihydrochloride monohydrate commercially available tablets, immediate release tablets (1.50 and 0.125 mg) and sustained release tablets (0.52 mg), to quantify the main component in the tablets. The amount of distomer could be quantified in bulk sample materials.
📜 SIMILAR VOLUMES
## Abstract A capillary electrophoresis method for the enantiomeric purity determination of SLV307, a basic potential antipsychotic compound, has been developed and validated. It is shown that the presence of the eutomer in the sample solution may have a significant effect on the peak shape of the
## Abstract A stereoselective CE assay for the determination of the enantiomeric purity of (__R__)‐(−)‐chloroquine and (__S__)‐(+)‐chloroquine was developed and validated. The separations were performed in a 50.2/40 cm uncoated fused silica capillary at 20°C using a 100 mM sodium phosphate buffer,
## Abstract A new and accurate HPLC method using β‐cyclodextrin chemically bonded to spherical silica particles as chiral stationary phase (CSP) was developed and validated for determination of __S__‐clopidogrel and its impurities __R__‐enantiomer and __S__‐acid as a hydrolytic product. The effects