A new functional membrane which changes its reflectance spectra according to the pH of the test solution is described. A chloromethylstyrene (CMS)/methylmethacrylate (MMA) copolymer was chosen as the base for the immobilized reagent. A basic ion-exchanger was then added to the CMS/MMA copolymer. Bro
Development and investigation of an optical tilt sensor
β Scribed by Z.W. Zhong; L.P. Zhao; H.H. Lin
- Publisher
- Elsevier Science
- Year
- 2006
- Tongue
- English
- Weight
- 158 KB
- Volume
- 261
- Category
- Article
- ISSN
- 0030-4018
No coin nor oath required. For personal study only.
β¦ Synopsis
An optical tilt sensor was developed and its performance was investigated. The tilt sensor set-up consisted of a laser light source, lenses and an image sensor. A precision reference tilt sensor was also installed on the same stage, and the measurement results of tilt angles using the optical and reference tilt sensors were correlated. The correlation coefficient (R-value) obtained under ideal conditions was 0.99454, indicating that the optical tilt sensor could produce as accurate measurements as the precision reference tilt sensor. The R-value decreased to 0.97714 and 0.93209 when the image sensor was shifted backwards and forwards from the focal plane by 1 mm, respectively. The R-value decreased to 0.96840 when the tilt sensor was performed with the room light turned on. There were not significant differences in the measurement results obtained with air conditioners turned on and off, indicating that the optical tilt sensor was robust and was not sensitive to the surrounding air turbulence. These findings are useful for the final design of the optical tilt sensor.
π SIMILAR VOLUMES
## Abstract The development of a fluorescent excitation ratiometric pH sensor (AHQβPEG) using a novel allylhydroxyquinolinium (AHQ) derivative copolymerized with polyethylene glycol dimethacrylate (PEG) is described. The AHQβPEG sensor film is shown to be suitable for realβtime, noninvasive, contin
An optsal-chemical sensor for momtormg ammomum Ions m aqueous solutions was developed The propertles of the sensor, which IS based on an lmmobdized pH mdlcator were investigated For the munoblhzat~on microporous PTFE membranes were used and the changes m the reflectance spectra were measured The det
## Abstract In this work, an angular sensor using optical fiber is achieved. The principle of attenuation of the intensity of the luminous wave in the optical fiber (curved to deduct the angle of curvature) is used. A mechanical system controlled by a PC is conceived to simulate the articulation of