Development and application of an excitation ratiometric optical pH sensor for bioprocess monitoring

✍ Scribed by Ramachandram Badugu; Yordan Kostov; Govind Rao; Leah Tolosa


Publisher
American Institute of Chemical Engineers
Year
2008
Tongue
English
Weight
348 KB
Volume
24
Category
Article
ISSN
8756-7938

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The development of a fluorescent excitation ratiometric pH sensor (AHQ‐PEG) using a novel allylhydroxyquinolinium (AHQ) derivative copolymerized with polyethylene glycol dimethacrylate (PEG) is described. The AHQ‐PEG sensor film is shown to be suitable for real‐time, noninvasive, continuous, online pH monitoring of bioprocesses. Optical ratiometric measurements are generally more reliable, robust, inexpensive, and insensitive to experimental errors such as fluctuations in the source intensity and fluorophore photobleaching. The sensor AHQ‐PEG in deionized water was shown to exhibit two excitation maxima at 375 and 425 nm with a single emission peak at 520 nm. Excitation spectra of AHQ‐PEG show a decrease in emission at the 360 nm excitation and an increase at the 420 nm excitation with increasing pH. Accordingly, the ratio of emission at 420:360 nm excitation showed a maximum change between pH 5 and 8 with an apparent pK~a~ of 6.40. The low pK~a~ value is suitable for monitoring the fermentation of most industrially important microorganisms. Additionally, the AHQ‐PEG sensor was shown to have minimal sensitivity to ionic strength and temperature. Because AHQ is covalently attached to PEG, the film shows no probe leaching and is sterilizable by steam and alcohol. It shows rapid (∼2 min) and reversible response to pH over many cycles without any photobleaching. Subsequently, the AHQ‐PEG sensor film was tested for its suitability in monitoring the pH of S. cereviseae (yeast) fermentation. The observed pH using AHQ‐PEG film is in agreement with a conventional glass pH electrode. However, unlike the glass electrode, the present sensor is easily adaptable to noninvasive monitoring of sterilized, closed bioprocess environments without the awkward wire connections that electrodes require. In addition, the AHQ‐PEG sensor is easily miniaturized to fit in microwell plates and microbioreactors for high‐throughput cell culture applications.


📜 SIMILAR VOLUMES


Development of biosensors based on an el
✍ C. Menzel; T. Lerch; T. Scheper; K. Schügerl 📂 Article 📅 1995 🏛 Elsevier Science 🌐 English ⚖ 452 KB

Simple non-structured fluoride sensitive electrolyte isolator semiconductor (EIS) chips consisting of Si/SiO,/Si,N,/LaF, layers were used as transducers for measuring the H,O, concentration by peroxidase (POD) and combined this H,O, sensor with various oxidases, which form H,O, in stoichiometric amo