๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Determination of volatile arsenicals in ambient air by flow injection

โœ Scribed by Joseph H. Aldstadt; Don C. Olson; Alice F. Martin


Publisher
Elsevier Science
Year
1997
Tongue
English
Weight
750 KB
Volume
338
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

โœฆ Synopsis


We report the development of a method for determining truns-dichloro(2-ch1orovinyl)arsine (Lewisite) in ambient air in near real time. Air monitoring of Lewisite is required to support arms control treaty inspections, weapons destruction processes, and remediation of hazardous waste sites. Flow injection (FI) techniques are used to integrate a gas permeation membrane (CPM) sampling unit to a detector based on the constant-current mode of potentiometric stripping analysis (PSA). The method indirectly measures Lewisite in ambient air by collecting vapor-phase Lewisite across a thin-walled rubber membrane and hydrolyzing it to form arsenite ion for detection by PSA. We tested silicone and natural rubber nonporous membranes with estimated wall thicknesses of 0.66 and 0.27 mm, respectively. The rubber GPM tubes are oriented linearly in the sampler, and the sample is collected at a flow rate of 200 mllmin through the cavity. We studied arsenic trichloride as a vapor-phase simulant for Lewisite, although we found its silicone rubber permeability characteristics unfavorable. Factors including membrane tube length, sampling time, and sampling temperature were examined during experiments in which vapor-phase Lewisite was generated at 0.99 ppb,. The typical response to Lewisite was fast (within one sampling cycle) and continuous readings to vapor-phase Lewisite measurements were stable (~20% relative standard deviation). On the basis of this testing, we estimate a working range for Lewisite from 0.5 to 50 uglms using a 15 min total cycle time.


๐Ÿ“œ SIMILAR VOLUMES


Two-dimensional gas chromatography for d
โœ Berg, S. ;Jonsson, A. ๐Ÿ“‚ Article ๐Ÿ“… 1984 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 691 KB

A two-diemnsional gaschromatograph is described for the analysis of volatile compounds. The chromatographic system consists of two separate chromatographs linked together with an interface containing an intermediate trap. The trap is cooled with nitrogen (-150OC) and a cryogradient is created inside

Determination of trimethylamine nitrogen
โœ Ruiz-Capillas, C; Horner, W?F?A ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 83 KB ๐Ÿ‘ 2 views

There are many chemical, microbiological and sensory indices of ยฎsh quality. Of the chemical indices, TMA-N and TVB-N are probably the most used in connection with remaining shelflife determination. This paper reports on a study of modiยฎcations to a ยฏow injection analysis (FIA) method necessary to m

Determination of arsenic by hydride gene
โœ J.R. Farrell; P.J. Iles; Y.J. Yuan ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 407 KB

Hydride generation gas diffusion flow injection analysis with two different electrochemical detectors -conductometric or amperometric -has been investigated for the determination of arsenic. With amperometric detection, where a detection limit (signal-to-noise ratio = 3) of 0.01 mg 1-l As was achiev