A kinetic method for the simultaneous determination of magnesium and calcium ions in solution is described. The method is based on the dissociation reactions of cryptand (2.2.2) complexes; a stopped-flow injection technique is used with spectrophotometric monitoring of the phthalein complexone compl
Determination of traces of calcium and magnesium in rare earth oxides by flow-injection analysis
β Scribed by Duong Thanh Thuy; Dini Decnop-Weever; Win Th. Kok; Pham Luan; Tu Vong Nghi
- Publisher
- Elsevier Science
- Year
- 1994
- Tongue
- English
- Weight
- 586 KB
- Volume
- 295
- Category
- Article
- ISSN
- 0003-2670
No coin nor oath required. For personal study only.
β¦ Synopsis
Flow-injection analysis has been applied for the determination of traces of calcium and magnesium in rare earth oxide samples. The method is based on the fluorescence of the calcein complexes of calcium and magnesium in a solution with high pH. The analyte ions are separated from the rare earth ion matrix on an in-line ion-exchange column. Matrix concentrations up to 500 mg 1-l of rare earth ions can be used. To discriminate between calcium and magnesium, 8-hydroxyquinoline is used as mashing agent for magnesium and EGTA for calcium. Without masking agent the sum of calcium and magnesium is obtained. The relative standard deviation of the peak height for 25 pmol I-' calcium was 0.4%. The lower limits of determination are 2 pmol 1-l or 0.1 mg g-' in the rare earth oxide for calcium and 1 pmoll-l or 0.04 mg g-* for magnesium. Results obtained with the proposed method agree well with inductively coupled plasma atomic emission spectrometric results for a raw rare earth oxide sample
π SIMILAR VOLUMES
Magnesmm was determined m a flow-mqectlon system by formatlon of the magnesmm-Enochrome Black T (EBT) complex at pH 115 (5% 1,Zdlammoethane m 0 1 M KCl) and amperometrlc measurement of the excess of EBT at +0 175 V on a glassy carbon electrode From modelhng calculations, pH and concentrations of EBT
The design, development, and testing of a flow-injection analysis (FIA) manifold for the simultaneous determination of two species in milk samples is reported. Calcium is determined potentiometrically, and, following on-line sample treatment, spectrophotometric analysis of phosphorus is performed. R
A sequential injection analysis system for the determination of calcium in water, urine and pharmaceutical samples is proposed. The method is based on the fast complexation reaction between cresolphthalein complexone and calcium with spectrophotometric detection. Baseline shift due to a background o
A flow-injection analysis method is described for the determination of trace levels of aluminum using fluorescent detection of the Al-lumogallion complex. The method is very simple, requiring neither iron masking agents nor micelle forming compounds to improve sensitivity. The detection limit is 3.7
## Abstract A sensitive analytical method based on gasβdiffusion flow injection system for ammonium ion determination at trace levels with capacitively coupled contactless conductivity detection (C^4^D) is described. The effects of the chemical composition of the acceptor stream, operating frequenc