✦ Synopsis


Flow-injection analysis has been applied for the determination of traces of calcium and magnesium in rare earth oxide samples. The method is based on the fluorescence of the calcein complexes of calcium and magnesium in a solution with high pH. The analyte ions are separated from the rare earth ion matrix on an in-line ion-exchange column. Matrix concentrations up to 500 mg 1-l of rare earth ions can be used. To discriminate between calcium and magnesium, 8-hydroxyquinoline is used as mashing agent for magnesium and EGTA for calcium. Without masking agent the sum of calcium and magnesium is obtained. The relative standard deviation of the peak height for 25 pmol I-' calcium was 0.4%. The lower limits of determination are 2 pmol 1-l or 0.1 mg g-' in the rare earth oxide for calcium and 1 pmoll-l or 0.04 mg g-* for magnesium. Results obtained with the proposed method agree well with inductively coupled plasma atomic emission spectrometric results for a raw rare earth oxide sample


πŸ“œ SIMILAR VOLUMES


Kinetic determination of magnesium and c
✍ Henrik Kagenow; Arne Jensen πŸ“‚ Article πŸ“… 1983 πŸ› Elsevier Science 🌐 English βš– 548 KB

A kinetic method for the simultaneous determination of magnesium and calcium ions in solution is described. The method is based on the dissociation reactions of cryptand (2.2.2) complexes; a stopped-flow injection technique is used with spectrophotometric monitoring of the phthalein complexone compl

Amperometric techniques in flow-injectio
✍ Alison J. Downard; Joanne B. Hart; H.Kipton J. Powell; Shuanghua Xu πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 712 KB

Magnesmm was determined m a flow-mqectlon system by formatlon of the magnesmm-Enochrome Black T (EBT) complex at pH 115 (5% 1,Zdlammoethane m 0 1 M KCl) and amperometrlc measurement of the excess of EBT at +0 175 V on a glassy carbon electrode From modelhng calculations, pH and concentrations of EBT

Simultaneous determination of total calc
✍ Telis Dimitrakopoulos; John R. Farrell; Peter J. Iles πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 143 KB πŸ‘ 2 views

The design, development, and testing of a flow-injection analysis (FIA) manifold for the simultaneous determination of two species in milk samples is reported. Calcium is determined potentiometrically, and, following on-line sample treatment, spectrophotometric analysis of phosphorus is performed. R

Determination of calcium in water, urine
✍ J.F. van Staden; R.E. Taljaard πŸ“‚ Article πŸ“… 1996 πŸ› Elsevier Science 🌐 English βš– 1011 KB

A sequential injection analysis system for the determination of calcium in water, urine and pharmaceutical samples is proposed. The method is based on the fast complexation reaction between cresolphthalein complexone and calcium with spectrophotometric detection. Baseline shift due to a background o

Determination of trace aluminum in natur
✍ Susan H. Sutheimer; Stephen E. Cabaniss πŸ“‚ Article πŸ“… 1995 πŸ› Elsevier Science 🌐 English βš– 965 KB

A flow-injection analysis method is described for the determination of trace levels of aluminum using fluorescent detection of the Al-lumogallion complex. The method is very simple, requiring neither iron masking agents nor micelle forming compounds to improve sensitivity. The detection limit is 3.7

Trace Levels Determination of Ammonium b
✍ Henrique L. Braz; DΓ©bora T. Ito; JosΓ© A. Fracassi daβ€…Silva; Claudimir L. doβ€…Lago πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 277 KB πŸ‘ 1 views

## Abstract A sensitive analytical method based on gas‐diffusion flow injection system for ammonium ion determination at trace levels with capacitively coupled contactless conductivity detection (C^4^D) is described. The effects of the chemical composition of the acceptor stream, operating frequenc