✦ Synopsis


Flucofuron and sulcofuron, both examples of mitins, have been employed as the active ingredients in mothproofing formulations for the protection of textile fabrics by the dyeing industry. Monitoring of their presence in components of the river ecosystem is a regulatory requirement so that sensitive detection techniques are required to obtain valid data concerning the levels of target pollutants present. Several methods have previously been reported for their determination but most of these methods are either inefficient or meet with some difficulty when dealing with trace residues in environmental matrices. This study has focused on the development of a highly sensitive and specific method of detection for these analytes, employing liquid chromatography combined with negative-ion electrospray ionization mass spectrometry operated in multiple-reaction monitoring (MRM) mode. Linearity was observed for both analytes (2.5-2500pg) with correlation coefficients of 0.999 obtained routinely. The absolute instrumental limits of detection in MRM mode, defined as a signal-to-noise ratio of 3:1, were calculated to be 2.5pg and 10pg for flucofuron and sulcofuron, respectively.


📜 SIMILAR VOLUMES


Quantitative determination of DNA adduct
✍ Siethoff, Christoph; Feldmann, Ingo; Jakubowski, Norbert; Linscheid, Michael 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 147 KB 👁 2 views

The quantitative determination of nucleotides from DNA modiÐed by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liqui

Determination of anabolic steroids by ga
✍ Man Ho Choi; Bong Chul Chung; Won Lee; Un Chul Lee; Yunje Kim 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 118 KB 👁 1 views

A gas chromatography/mass spectrometry (GC/MS) method is described which uses negative ion chemical ionization (NCI) and tandem mass spectrometry (MS/MS) for the determination of eight anabolic steroids in human urine. Eight anabolic steroids were derivatized by heptafluorobutyric anhydride (HFBA),

High performance liquid chromatography c
✍ Adriano Marcelli; Donata Favretto; Pietro Traldi 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 183 KB 👁 2 views

## Two (methoxymethyl)melamine resins of industrial and commercial interest have been analysed by means of high performance liquid chromatography (HPLC)/electrospray ionization ion trap mass spectrometry in order to identify the components of the complex mixtures which are produced by melamine res

Determination of four anabolic steroid m
✍ Man Ho Choi; Bong Chul Chung; Myungsoo Kim; Jeongeun Choi; Yunje Kim 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 164 KB 👁 1 views

A gas chromatography/mass spectrometry method is described which uses negative ion chemical ionization and tandem mass spectrometry for the determination of anabolic steroid metabolites. Four anabolic steroid metabolites to be derivatized by Pentafluoropropionic anhydride (PFPA) were determined usin