Determination of stability constants of metal complexes with potentiometric pH titrations
β Scribed by G. Anderegg
- Publisher
- Elsevier Science
- Year
- 1993
- Tongue
- English
- Weight
- 402 KB
- Volume
- 282
- Category
- Article
- ISSN
- 0003-2670
No coin nor oath required. For personal study only.
β¦ Synopsis
The use of different cells for pH measurements for the determination of equilibrium constants of metal complexes is discussed in relation to the liquid junction potential connected with them. The effects of Hf and OH, on this quantity are also considered. The literature values for the conversion factor A, representing the difference in pH value based on the calibration with NBS buffers and that defined in terms of H+ concentration, are discussed.
π SIMILAR VOLUMES
The use of rapid gradient flow-injection titration for the determination of equilibrium constants in solution, previously used in pK measurements of monobasic and multibasic weak acids is extended to the more demanding case of metal complexation. Formation constants for the complexes ML and ML, of
## Autoprotolysis constants and correction factors for a glass electrode in lo-508 (v/v) dioxane-water mixtures were calculated by using a procedure based on the titration of a strong acid with a strong base in the studied media. The correction factors were obtained at each titration point and the