We discovered that 4-(2-pyridylazo) resorcinol (PAR) has a strong catalytic effect on luminol-potassium ferricyanide chemiluminescence (CL). Results indicated that the chemiluminescence intensities at maximum light emission were linearly corrected with the concentration of PAR over the range 1.0 x 1
Determination of rutin by flow injection chemiluminescence method using the reaction of luminol and potassium hexacyanoferrate(III) with the aid of response surface methodology
✍ Scribed by Dan Yang; Haiyun Li; Ziyuan Li; Zaibin Hao; Jianping Li
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 824 KB
- Volume
- 25
- Category
- Article
- ISSN
- 1522-7235
- DOI
- 10.1002/bio.1172
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A novel flow injection chemiluminescence (CL) method for the determination of rutin was reported. The proposed method was based on the enhanced effect of rutin on the chemiluminescence intensity of luminol and potassium hexacyanoferrate(III) reaction in NaOH medium. The variables of reaction system, such as luminol concentration, potassium hexacyanoferrate(III) concentration and NaOH concentration, were optimized with the aid of response surface methodology. For the responses prediction, a second‐order polynomial model (SOPM) was applied. The optimal conditions for determination of rutin estimated by the model equation were as follows: NaOH concentration of 0.13 mol/L luminol concentration of 0.94 × 10^−6^ mol/L, and K~3~Fe(CN)~6~ concentration of 1.09 × 10^−4^ mol/L. The theoretical increased ratio of CL intensity (IRI) predicted and actual IRI for 0.05 mg/L rutin under the above conditions were 99.40 and 99.74%, respectively. The SOPM model proved to be powerful for navigating the design space. Under the above optimum conditions, the increased IRI was linearly related to the concentration of rutin in the range from 0.008 to 0.100 mg/L with the regression equation IRI = 1948.20__c__ + 5.24 (r = 0.9994) and in the range from 0.100 to 1.000 mg/L with the regression equation IRI = 1362.50 c + 61.94 (r = 0.9996). The detection limit (3__σ__) was of 1.95 × 10^−3^ mg/L. The sampling frequency of this method was 72/h. The method was used directly to determine rutin in tablets. Copyright © 2009 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract In this work, a new flow injection chemiluminescence method is described for the determination of ampicillin and amoxycillin. The method is based on the strong enhancing effects of these antibiotics on the luminol–periodate reaction. The present method allows the measurements of ampicil