Methylphenidate (MPH; Ritalin: methyl-alpha-phenyl-2-piperidinacetate hydrochloride) is utilized for the treatment of attention deficit hyperactivity disorder (ADHD) and narcolepsy. Recently, we described a rapid enantioselective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for t
Determination of (R)- and (S)-ketoprofen in human plasma by liquid chromatography/tandem mass spectrometry following automated solid-phase extraction in the 96-well format
โ Scribed by Eichhold, Thomas H.; Bailey, Ruth E.; Tanguay, Suzanne L.; Hoke, Steven H.
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 113 KB
- Volume
- 35
- Category
- Article
- ISSN
- 1076-5174
No coin nor oath required. For personal study only.
โฆ Synopsis
A sensitive and selective method was developed for the determination of (R)-ketoprofen ((R)-kt) and (S )-ketoprofen ((S )-kt) in human plasma using chiral liquid chromatography/tandem mass spectrometry (LC/MS/MS). Plasma samples spiked with stable-isotope-labeled [ 13 C 1 , 2 H 3 ]-(R and S )-ketoprofen, for use as the internal standards, were prepared for analysis using automated solid-phase extraction (SPE) in the 96-well microtiter format. The enantiomers were separated on an (R)-1-naphthylglycine and 3,5-dinitrobenzoic acid (Chirex 3005) 250 ร 2.0 mm i.d. analytical column, equipped with a 30 ร 2.0 mm i.d. guard column using isocratic mobile phase conditions. The (R)-and (S )-kt levels were quantifiable from 0.05 to 2500 ng ml -1 by constructing two separate curves from calibration standards covering the same range. The first curve ranged from 0.05 to 100 and the second from 100 to 2500 ng ml -1 . A concentration of 0.05 ng ml -1 of either enantiomer was easily detected using a 1 ml plasma sample volume. The average method accuracy, evaluated at four levels over an extended period, was better than ยฑ3% over the entire range. The precision for the same set of quality control samples ranged from 4.0 to 7.0% RSD (n = 24). The method was applied to the evaluation of pharmacokinetic parameters in human plasma obtained from volunteers who received 25 mg of kt by peroral administration of Actron caplets or by topical administration of Oruvail gel.
๐ SIMILAR VOLUMES
A sensitive, specific, accurate and reproducible analytical method was developed and validated for the quantitation of the anticancer agent paclitaxel in human plasma. This procedure is based on high performance liquid chromatography/ion spray -tandem mass spectrometry. This methodology is highly sp
For biological monitoring of hospital personnel occupationally exposed to antineoplastic agents, highly sensitive and specific methods are required. In order to detect trace MTX urinary concentrations, a precise and accurate high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS
A sensitive and entirely automated solid-phase extraction/liquid chromatography/electrospray ionization tandem mass spectrometric (SPE/LC/ESI-MS/MS) method was developed and validated for the determination of eserine N -oxide (ENO), a cholinesterase inhibitor-like physostigmine in human plasma, for
A mass spectrometry based method for the simultaneous determination of an in vivo Greenford-Ware or 'GW cocktail' of CYP450 probe substrates and their metabolites in both human plasma and urine is described. The probe substrates, caffeine, diclofenac, mephenytoin, debrisoquine, chlorzoxazone and mid