𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Determination of polychlorodibenzo-p-dioxins and polychlorodibenzofurans by gas chromatography/tandem mass spectrometry and gas chromatography/triple mass spectrometry in a quadrupole ion trap

✍ Scribed by C. Helen; M. Lemasle; A. Laplanche; E. Genin


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
377 KB
Volume
36
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The determination of tetra‐ to octachlorodibenzo‐p‐dioxins and tetra‐ to octachlorodibenzofurans (PCCD/Fs) by high‐resolution gas chromatography/tandem mass spectrometry (HRGC/MS/MS) and high‐resolution gas chromatography/triple mass spectrometry (HRGC/MS^3^) in a quadrupole ion trap, equipped with an external ion source, is presented. MS/MS involves a typical four‐step process, namely ionization, parent ion isolation, collision‐induced dissociation (CID) and mass analysis of the daughter ions. For the MS^3^ experiment, the MS/MS scan function is used with the addition of selected daughter ion isolation, their CID and the mass analysis of second‐generation product ions called ‘grand‐daughter ions.’ For both methods, the energies necessary for the CID of the 17 PCDD/Fs were determined and optimized using multiple scan functions with different CID amplitudes. The CID efficiency, defined as the signal ratio of fragment ions detected from the major dissociation channels to molecular ions isolated, was 1.15–2.40 V for parent ion dissociation (MS/MS) and 1.05–1.50 V for daughter ion dissociation (MS^3^) and for all the chloro congeners. The same sensitivity (1 pg µl^−1^) can be reached with both the MS/MS and MS^3^ methods and linear responses were obtained between 1 and 100 pg µl^−1^ injected. Copyright © 2001 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Analysis of alkenes by copper ion chemic
✍ Fordham, P. J.; Chamot-Rooke, J.; Giudice, E.; Tortajada, J.; Morizur, J.-P. 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 164 KB 👁 2 views

A novel chemical ionization/fast atom bombardment (CI/FAB) source was used to analyse alkenes by chemical ionization mass spectrometry (CI-MS) using copper ions as the ionizing agent. The Cu Y -CI mass spectra showed abundant pseudomolecular adduct ions [alkene-Cu] Y and characteristic fragment ions

Ion trap mass spectrometry of trimethyls
✍ Gee, Andrew J.; Groen, Lisa A.; Johnson, Mitchell E. 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 95 KB 👁 2 views

Fatty acid amides are a class of compounds with newly discovered biological activity. The ion trap mass spectrometric characteristics of silylated fatty acid amides were examined. Silylation of primary fatty acid amides is required prior to gas chromatography owing to thermal instability of the unde

High performance liquid chromatography q
✍ Martin J. Egan; Elaine A. Porter; Geoffrey C. Kite; Monique S. J. Simmonds; Jame 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 97 KB 👁 1 views

A crudely purified polyhydroxyalkaloid (PHA) extract of Hyacinthoides non-scripta (Hyacinthaceae) was studied by gas chromatography/mass spectrometry (GC/MS), liquid chromatography/sequential mass spectrometry (LC/MS n ) and direct infusion atmospheric pressure chemical ionisation-mass spectrometry

Analysis of Thermally Labile Pesticides
✍ Adam Vincze; Jehuda Yinon 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 526 KB

Gas chromatographyfion-trap mass spectrometry in the electron ionization (EI) mode, with a cooled temperature-programmable injector, has been used for the analysis of a series of thermolabile carbamate and phenylurea pesticides. The mass spectra were found to be in good agreement with 70eV solid-pro

Determination of anabolic steroids by ga
✍ Man Ho Choi; Bong Chul Chung; Won Lee; Un Chul Lee; Yunje Kim 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 118 KB 👁 2 views

A gas chromatography/mass spectrometry (GC/MS) method is described which uses negative ion chemical ionization (NCI) and tandem mass spectrometry (MS/MS) for the determination of eight anabolic steroids in human urine. Eight anabolic steroids were derivatized by heptafluorobutyric anhydride (HFBA),

Quantitative gas chromatography/tandem m
✍ Christian Andalò; Guido C. Galletti; Paola Bocchini 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 109 KB 👁 2 views

In ion trap mass spectrometry, collisional experiments are easily performed by precursor ion selection and software controlled operations. Collisional activation can be achieved by two different approaches, resonant and non-resonant excitation. Different results are usually obtained by the two appro