𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Determination of dopamine and serotonin in human urine samples utilizing microextraction online with liquid chromatography/electrospray tandem mass spectrometry

✍ Scribed by Aziza El-Beqqali; Anders Kussak; Mohamed Abdel-Rehim


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
331 KB
Volume
30
Category
Article
ISSN
1615-9306

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A specific LC‐MS‐MS method for the determination of dopamine and serotonin (5‐hydroxytryptamine; 5HT) in human urine is described. The analytes were extracted from urine and preconcentrated by microextraction in a packed syringe (MEPS). The new method is very promising, very easy to use, fully automated, of low cost, and rapid in comparison to previously used methods. The method was validated and the standard curves were evaluated by means of quadratic regression and weighted by inverse of the concentration: 1/x for the calibration range 50–4000 ΞΌg/L. The MEPS applied polymer (silica‐C8) could be used more than 300 times. The extraction recovery was about 50%. The results showed close correlation coefficients (r^2^ >0.999) for all analytes in the calibration range studied. The accuracy of MEPS‐LC‐MS‐MS was 100–101% for dopamine and 99–100% for 5HT. The interday precision (n = 3 days), expressed as the RSD%, was 6.0–7.7% for dopamine and 6.1–11% for 5HT. MEPS reduced the handling time by 12 times compared to a published method.


πŸ“œ SIMILAR VOLUMES


Determination of ethyl glucuronide in ha
✍ Luca Morini; Lucia Politi; Angelo Groppi; Cristiana Stramesi; Aldo Polettini πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 214 KB πŸ‘ 2 views

## Abstract A method for the determination of ethyl glucuronide (EtG) in hair samples, using liquid chromatography/electrospray tandem mass spectrometry (LC/ESI‐MS/MS), was developed and validated. The treatment of hair samples was as follows: to 100 mg of washed (dichloromethane followed by methan

Electrospray ionization mass spectrometr
✍ Carlo Giorgio Zambonin; Francesco Palmisano πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 79 KB πŸ‘ 2 views

The behaviour of 5-methyl-2'-deoxycytidine (m 5 dCyd, claimed to be a potential marker for leukaemia) during the electrospray process was studied. In particular, considerations concerning the effect of solution chemistry (e.g. analyte concentration, pH, etc.) on electrospray ionization mass spectra

Determination of LTE4 in Human Urine By
✍ Wu, Yunhui; Li, Lily Y.-T.; Henion, Jack D.; Krol, George J. πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 578 KB

A sensitive and specific high-performance liquid chromatographic/ionspray tandem mass spectrometric (LC/ionspray MS/MS) method was developed and validated to quantitate leukotriene E, (LTE,) in human urine. This method involves solid-phase extraction with Empore membrane disks to isolate LTE, and it

Quantification of ropivacaine and its ma
✍ Mohamed Abdel-Rehim; Marie Dahlgren; Lars Blomberg πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 481 KB

Quantification of ropivacaine and its major metabolites in human urine samples utilizing microextraction in a packed syringe automated with liquid chromatography-tandem mass spectrometry (MEPS-LC-MS/MS) The determination of ropivacaine and its major metabolites in urine was performed using microext