✦ Synopsis


A preliminary study of an in situ nebulizer-hydride generator as a sample introduction device for an inductively coupled plasma mass spectrometry (ICP-MS) system is described. The samples were ionic arsenic compounds that had undergone chromatographic separation before injection into the hydride generator. L-Qsteine was used instead of potassium iodide as the prereductant. Only mild treatment with nitric acid was necessary to obtain a satisfactory hydride efficiency. The sensitivity, detection limits and reproducibility of a liquid chromatographic (LC)-ICP-MS system with a hydride generator were comparable to or better than an LC-ICP-MS system with conventional pneumatic nebulization or other sample introduction techniques. The limits of detection for various arsenic species were in the range 11-51 ng 1-l. The concentrations of various arsenic species in several natural water samples were determined.


📜 SIMILAR VOLUMES


Determination of arsenic speciation by l
✍ R. Rubio; A. Padró; J. Albertí; G. Rauret 📂 Article 📅 1993 🏛 Elsevier Science 🌐 English ⚖ 573 KB

The determination is described of the six arsenic species arsenite, arsenate, monomethylarsonate (MMA), dimethylarsinate (DMA), arsenobetaine and arsenocholine by hydride generation inductively coupled plasma atomic emission spectrometry after liquid chromatographic separation and on-line photooxida

Determination of arsenic compounds in ma
✍ W. Goessler; A. Rudorfer; E. A. Mackey; P. R. Becker; K. J. Irgolic 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 158 KB 👁 2 views

Total arsenic concentrations and the concentrations of individual arsenic compounds were determined in liver samples of pinnipeds [nine ringed seals (Phoca hispida), one bearded seal (Erginathus barbatus)] and cetaceans [two pilot whales (Globicephalus melas), one beluga whale (Deliphinapterus leucu

Simultaneous determination of arsenic(V)
✍ Yong-lai Feng; Jian-ping Cao 📂 Article 📅 1994 🏛 Elsevier Science 🌐 English ⚖ 595 KB

A small co-centric hydride generator can be used to determine arsenic by inductively coupled plasma atomic emission spectrometry with a minitorch of 0.65 kW power. Because the reaction of arsenic(V) with L-cysteine is linearly dependent on time up to 9 mitt, the determination of arsenic(V) based on

Determination of Butyltin Compounds in S
✍ Segovia García, E.; García Alonso, J. I.; Sanz-Medel, A. 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 326 KB 👁 2 views

A procedure for the determination of butyltin compounds in sediments is described. The method is based on the generation of volatile mono-, di-and tributyltin (MBT, DBT, TBT) hydrides from a 4% (v/v) acetic acid medium using The hydrides formed are then trapped on a Chromosorb W HP SP2100 packed gl

Determination of phenolic compounds in e
✍ Hakim Faraji; Syed W. Husain; Masoumeh Helalizadeh 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 221 KB 👁 1 views

## Abstract A novel approach for the sample pre‐treatment and determination of eight phenolic compounds in environmental water samples has been developed by hyphenating solid‐phase extraction (SPE) and liquid‐phase microextraction (LPME) techniques based on solid organic drop combined with gas chro