๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Determination of 60Co in environmental water samples by a hydrous magnesium oxide filter

โœ Scribed by Jem-Mau Lo; Jun-Der Lee


Publisher
Elsevier Science
Year
1996
Tongue
English
Weight
293 KB
Volume
318
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

โœฆ Synopsis


Preconcentration of trace '%o and analogous radionuclides by adsorption on MgO for their determination in environmental water samples exemplified by seawater was demonstrated. An adsorption filter fabricated by coating hydrous MgO onto a round piece of a densely twilled nylon cloth was used to facilitate separation of the radionuclides adsorbed. The MgO adsorption filter was sealed in a polyethylene column. The water sample analyzed was pumped through the column where the radionuclides could be efficiently adsorbed onto the filter. Thereafter the radionuclides enriched filter was transferred to a high-purity germanium detector connected with a multichannel analyzer for y-spectrometry.

The novel preconcentration technique proves to be fast and efficacious and detection of 60~ becomes highly sensitive because of the very large enrichment factor.


๐Ÿ“œ SIMILAR VOLUMES


Magnesium oxide microspheres as a novel
โœ Jing Jin; Zhiping Zhang; Jincheng Wang; Peipei Qi; Jiping Chen ๐Ÿ“‚ Article ๐Ÿ“… 2010 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 238 KB

## Abstract Magnesium oxide microspheres were developed as a novel SPE sorbent for the determination of benzo[a]pyrene (BaP), one of the most potent carcinogenic agents, in environmental water samples. The parameters controlling the extraction efficiency, such as elution volume, flow rate, pH value

Determination of low molecular weight al
โœ Djozan, Dj. ;Faraj-Zadeh, M. A. ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 444 KB

## Abstract A high resolution liquid chromatographic method is described for determination of low molecular weight (LMW) aliphatic amines in environmental waters. The analytes after isolation are derivatized by fluram and separated with isocratic elution on octyl (C~8~) column, followed by fluorime

A rapid method for the determination of
โœ Chuarn-Yuh Huang; Jun-Der Lee; Chia-Lian Tseng; Jem-Mau Lo ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 473 KB

This work deals with a simple, rapid, and efficacious design for the measurement of 137Cs in seawater . An adsorption filter is fabricated by coating copper(II) hexacyanoferrate(II) (CuCF) onto a densely twilled nylon cloth . The CuCF-nylon cloth filter is cut into round pieces and screwed into a po