Determination of 3-Nitrotyrosine by High-Pressure Liquid Chromatography with a Dual-Mode Electrochemical Detector
β Scribed by Rama S. Sodum; Shobha A. Akerkar; Emerich S. Fiala
- Publisher
- Elsevier Science
- Year
- 2000
- Tongue
- English
- Weight
- 94 KB
- Volume
- 280
- Category
- Article
- ISSN
- 0003-2697
No coin nor oath required. For personal study only.
β¦ Synopsis
3-Nitrotyrosine, a product of tyrosine nitration, is useful as a marker for the generation of reactive nitrogen oxide species with short half-lives such as peroxynitrite. A reverse-phase high-pressure liquid chromatographic method using a dual-mode electrochemical detector in series with a photodiode array detector has been developed to determine the levels of 3-nitrotyrosine in biological samples. The principle of this method involves reduction of 3-nitrotyrosine at an upstream gold amalgam electrode and oxidation of the resulting product(s) at a downstream glassy carbon electrode. 3-Nitrotyrosine is quantified by the amount of the current generated at the downstream electrode, and a femtomole detection level can be achieved. The disappearance of the corresponding peak when the electrochemical detector is used only in the single oxidative mode provides additional evidence for the identity of 3-nitrotyrosine in the sample. Tyrosine from the same sample is determined by its UV absorption at 280 nm, thus eliminating the need for an internal standard. With this method a dose-dependent increase of 3- to 10-fold in the levels of protein 3-nitrotyrosine was observed in the blood plasma, and a 2- to 4-fold increase in the lung cytosols, of rats treated with the lung carcinogen and nitrating agent tetranitromethane.
π SIMILAR VOLUMES
A new, sensitive, and specific assay method for guanine nucleotides using high-performance liquid chromatography with dual-electrochemical detection was developed. GTP, GDP, GMP, and cyclic GMP were separated with reversed-phase "ion-pair" chromatography and detected by a dual-electrochemical detect
The determination of trace p-nitrophenol (PNP) concentrations in human urine has been successfully achieved by high performance liquid chromatography dual electrode detection (LC-DED) in the reduction-reduction mode. Initial cyclic voltammetric studies were undertaken to investigate the electrochemi
A simple and sensitive assay method for NO synthase activity is described. Using glassy carbon as electrode and 30% methanol solution with 10mM NH&I as mobile phase, NO, can be measured without disturbing ECD-detectable substance in NO synthase assay mixture. The NO; production in the assay mixture
A simple and sensitive high-performance liquid chromatography method with electrochemical detector is described for the determination of free 3-methoxy-4-hydroxyphenylacetic acid (HVA) in human plasma. The method does not involve any extraction, is specific and reproducible, and has the potential to