𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Detection of measles, mumps, and rubella antibodies in saliva using antibody capture radioimmunoassay

✍ Scribed by Keith R. Perry; Dr. David W. G. Brown; John V. Parry; Sohrab Panday; Christopher Pipkin; Alison Richards


Publisher
John Wiley and Sons
Year
1993
Tongue
English
Weight
606 KB
Volume
40
Category
Article
ISSN
0146-6615

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Antibody capture radioimmunoassays were developed for detecting virus specific IgM (MAC‐RIA) and IgG (GACRIA) to measles, mumps, and rubella and used to investigate saliva as an alternative specimen to serum for diagnosis.

Saliva was collected from 63 patients with measles, 19 with mumps, and 150 with rubella, which were all clinically diagnosed and serologically confirmed. Virus specific IgM was detected in 92% of measles, 75% of mumps, and 100% of rubella saliva samples collected during the first week of illness. Between 1 and 5 weeks after onset virus specific IgM was detected in 100% of saliva specimens. After the 5th week the proportion of reactive specimens declined.

The specificity of the MACRIA tests was established by testing saliva samples collected from blood donors for measles (88), mumps (88), and rubella IgM (91). All of the saliva specimens tested for measles and rubella specific IgM were unreactive, 1/88 specimens tested for mumps specific IgM contained significant reactivity. Saliva specimens collected from acute cases of MMR were tested in all 3 MACRIAs. A small proportion of saliva samples contained detectable IgM of more than one virus infection.

Rubella and measles specific IgG was detected in the saliva of all cases from the 4th or 5th day of illness, respectively. Detection of mumps specific IgG was less successful.

We have demonstrated that virus specific IgM can be reliably detected in saliva samples collected from acute cases of measles, mumps, and rubella and identified 1–5 weeks after onset of illness as the optimum time for collection of samples. Β© 1993 Wiley‐Liss, Inc.


πŸ“œ SIMILAR VOLUMES


Detection of acute measles infections by
✍ Hanna Tuokko πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 580 KB

## Abstract An avidity test for measles IgG was developed and applied to the study of IgG immunoglobulin maturation kinetics in follow‐up sera from 12 patients with known acute primary and convalescent measles and sera from blood donors. The avidity of the IgG anti‐measles responses was measured us

Detection and persistence of specific ig
✍ Emanuel Sikuler; Arieh Keynan; Negba Hanuka; Maureen G. Friedman; Dr. Israel Sar πŸ“‚ Article πŸ“… 1983 πŸ› John Wiley and Sons 🌐 English βš– 471 KB

The serum immunoglobulin A (IgA) response to hepatitis A virus (HAV) was investigated with a sensitive capture radioimmunoassay. In serial serum samples drawn from 15 patients with viral hepatitis A, IgA anti-HAV antibodies reached their highest titer between 1-2 weeks after onset and peak titers ra