𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Detection and validated quantification of nine herbal phenalkylamines and methcathinone in human blood plasma by LC-MS/MS with electrospray ionization

✍ Scribed by Jochen Beyer; Frank T. Peters; Thomas Kraemer; Hans H. Maurer


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
353 KB
Volume
42
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The herbal stimulants Ephedra species, Catha edulis (khat), and Lophophora williamsii (peyote) have been abused for a long time. In recent years, the herbal drug market has grown owing to publicity on the Internet. Some ingredients of these plants are also ingredients of cold remedies. The aim of the presented study is to develop a multianalyte procedure for detection and validated quantification of the phenalkylamines ephedrine, pseudoephedrine, norephedrine, norpseudoephedrine, methylephedrine, methylpseudoephedrine, cathinone, mescaline, synephrine (oxedrine), and methcathinone in plasma. After mixed‐mode solid‐phase extraction of 1 ml of plasma, the analytes were separated using a strong cation exchange separation column and gradient elution. They were detected using a Q‐Trap LC‐ESI‐MS/MS system (MRM mode). Calibration curves were used for quantification using norephedrine‐d~3~, ephedrine‐d~3~, and mescaline‐d~9~ as internal standards. The method was validated according to international guidelines. The assay was selective for the tested compounds. It was linear from 10 to 1000 ng/ml for all analytes. The recoveries were generally higher than 70%. Accuracy ranged from − 0.8 to 20.0%, repeatability from 2.5 to 12.3%, and intermediate precision from 4.6 to 20.0%. The lower limit of quantification was 10 ng/ml for all analytes. No instability was observed after repeated freezing and thawing or in processed samples. The applicability of the assay was tested by analysis of authentic plasma samples after ingestion of different cold medications containing ephedrine or pseudoephedrine, and after ingestion of an aqueous extract of Herba Ephedra. After ingestion of the cold medications, only the corresponding single alkaloids were detected in human plasma, whereas after ingestion of the herb extract, all six ephedrines contained in the plant were detected. The presented LC‐MS/MS assay was found applicable for sensitive detection and accurate and precise quantification of all studied analytes in plasma. Copyright © 2006 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Detection and validated quantification o
✍ Jochen Beyer; Frank T. Peters; Thomas Kraemer; Hans H. Maurer 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 288 KB 👁 1 views

## Abstract Poisonings with toxic plants may occur after abuse, intentional or accidental ingestion of plants. For diagnosis of such poisonings, multianalyte procedures were developed for detection and validated quantification of the toxic alkaloids aconitine, atropine, colchicine, coniine, cytisin

Determination of lipoic acid in rat plas
✍ Ravi Kumar Trivedi; Raja Reddy Kallem; Rao N. V. S. Mamidi; Ramesh Mullangi; Nug 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 149 KB 👁 2 views

## Abstract A simple, sensitive and specific LC‐MS/MS method for the determination of lipoic acid was developed and validated over the linearity range 5–1000 ng/mL (__r__^2^ > 0.99) with 200 µL rat plasma using rosigliatzone as an internal standard (IS). The assay procedure involved a simple one‐st

Development and validation of a sensitiv
✍ D. Vijaya Bharathi; Kishore Kumar Hotha; P. V. Vidya Sagar; S. Sirish Kumar; A. 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 396 KB 👁 2 views

## Abstract A highly sensitive and specific LC‐MS/MS method has been developed and validated for the estimation of pramipexole (PPX) with 500 µL human plasma using memantine as an internal standard (IS). The API‐4000 was operated under multiple‐reaction monitoring mode (MRM) using the electrospray

Development and validation of a sensitiv
✍ Ravi Kumar Trivedi; Pramod Kumar Dubey; Ramesh Mullangi; Nuggehally R. Srinivas 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 397 KB 👁 2 views

## Abstract A highly sensitive and specific LC‐MS/MS method has been developed and validated for the estimation of torcetrapib (TTB) with 100 µL hamster/dog plasma using DRL‐16126 as an internal standard (IS). The API‐4000 Q Trap LC‐MS/MS was operated under multiple‐reaction monitoring mode using t

Development and validation of a sensitiv
✍ Nimmagadda Sreenivas; M. Lakshmi Narasu; B. Prabha Shankar; Ramesh Mullangi 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 146 KB 👁 2 views

## Abstract A highly sensitive and specific LC‐MS/MS method has been developed and validated for the estimation of doxofylline (DFL) with 300 µL human serum using imipramine as the internal standard (IS). The API‐3000 LC‐MS/MS was operated under multiple reaction‐monitoring mode using the electrosp