๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Detecting defect in cast iron using high-TC SQUID

โœ Scribed by D.F. He; M. Yoshizawa; Y. Oyama; M. Nakamura


Publisher
Elsevier Science
Year
2004
Tongue
English
Weight
310 KB
Volume
412-414
Category
Article
ISSN
0921-4534

No coin nor oath required. For personal study only.

โœฆ Synopsis


For eddy-current NDE, due to the big permeability of ferromagnetic material, low testing frequency is needed to detect defects in it. SQUID has advantages in low frequency eddy current NDE. But the large magnetic field produced by ferromagnetic material often exceeds the dynamic range of general SQUID system. We developed a mobile high-T C SQUID system, with which, the dc and low-frequency magnetic field could be compensated well. Using our mobile SQUID system, the magnetic field produced by the cast iron could be compensated well and the defect in it could be successfully detected.