## Abstract Heart valve disease is a significant cause of mortality worldwide. However, to date, a nonthrombogenic, noncalcific prosthetic, which maintains normal valve mechanical properties and hemodynamic flow, and exhibits sufficient fatigue properties has not been designed. Current prosthetic d
Design and fabrication of heart muscle using scaffold-based tissue engineering
✍ Scribed by Nicole R. Blan; Ravi K. Birla
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 571 KB
- Volume
- 86A
- Category
- Article
- ISSN
- 1549-3296
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Cardiac tissue engineering strategies are based on the development of functional models of heart muscle in vitro. Our research is focused on evaluating the feasibility of different tissue engineering platforms to support the formation of heart muscle. Our previous work was focused on developing three‐dimensional (3D) models of heart muscle using self‐organization strategies and biodegradable hydrogels. To build on this work, our current study describes a third tissue engineering platform using polymer‐based scaffolding technology to engineer functional heart muscle in vitro. Porous scaffolds were fabricated by solubilizing chitosan in dilute glacial acetic acid, transferring the solution to a mold, freezing the mold at −80°C followed by overnight lyophilization. The scaffolds were rehydrated in sodium hydroxide to neutralize the pH, sterilized in 70% ethanol and cellularized using primary cardiac myocytes. Several variables were studied: effect of polymer concentration and chitosan solution volume (i.e., scaffold thickness) on scaffold fabrication, effect of cell number and time in culture on active force generated by cardiomyocyte‐seeded scaffolds and the effect of lysozyme on scaffold degradation. Histology (hematoxylin and eosin) and contractility (active, baseline and specific force, electrical pacing) were evaluated for the cellularized constructs under different conditions. We found that a polymer concentration in the range 1.0–2.5% (w/v) was most suitable for scaffold fabrication while a scaffold thickness of 200 μm was optimal for cardiac cell functionality. Direct injection of the cells on the scaffold did not result in contractile constructs due to low cell retention. Fibrin gel was required to retain the cells within the constructs and resulted in the formation of contractile constructs. We found that lower cell seeding densities, in the range of 1–2 million cells, resulted in the formation of contractile heart muscle, termed __s__mart __m__aterial __i__ntegrated __h__eart __m__uscle (SMIHMs). Chitosan concentration of 1–2% (w/v) did not have a significant effect on the active twitch force of SMIHMs. We found that scaffold thickness was an important variable and only the thinnest scaffolds evaluated (200 μm) generated any measurable active twitch force upon electrical stimulation. The maximum active force for SMIHMs was found to be 439.5 μN while the maximum baseline force was found to be 2850 μN, obtained after 11 days in culture. Histological evaluation showed a fairly uniform cell distribution throughout the thickness of the scaffold. We found that lysozyme concentration had a profound effect on scaffold degradation with complete scaffold degradation being achieved in 2 h using a lysozyme concentration of 1 mg/mL. Slower degradation times (in the order of weeks) were achieved by decreasing the lysozyme concentration to 0.01 mg/mL. In this study, we provide a detailed description for the formation of contractile 3D heart muscle utilizing scaffold‐based methods. We demonstrate the effect of several variables on the formation and culture of SMIHMs. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008
📜 SIMILAR VOLUMES
## Abstract **Summary:** Scaffold based tissue engineering strategies use cells, biomolecules and a scaffold to promote the repair and regeneration of tissues. Although scaffold‐based tissue engineering approaches are being actively developed, most are still experimental, and it is not yet clear wh
## Abstract Herein we report on the development and characterization of a biodegradable composite scaffold for ligament tissue engineering based on the fundamental morphological features of the native ligament. An aligned fibrous component was used to mimic the fibrous collagen network and a hydrog
## Abstract Tissue‐engineering scaffold‐based strategies have suffered from limited cell depth viability when cultured __in vitro__, with viable cells existing within the outer periphery of the fluid–scaffold interface. This is primarily believed to be due to the lack of nutrient delivery into and