Performance of the apparatus was evaluated in terms of stationary phase retention, partition efficiency and sample loading capacity. Preliminary studies with short coils revealed high retention of the stationary phase under a proper combination of the head-tail elution and planetary motion. Preparat
Cross-axis synchronous flow-through coil planet centrifuge for large-scale preparative counter-current chromatography : II. Studies on partition efficiency in short coils and preparative separations with multilayer coils
โ Scribed by Yoichiro Ito; Tian-you Zhang
- Publisher
- Elsevier Science
- Year
- 1988
- Tongue
- English
- Weight
- 501 KB
- Volume
- 449
- Category
- Article
- ISSN
- 1873-3778
No coin nor oath required. For personal study only.
โฆ Synopsis
A series of experiments was conducted to evaluate the partition efficiency of the cross-axis synchronous flow-through coil planet centrifuge. The preliminary studies indicated that short coils (5 m) mounted on 15-and 25-cm diameter holders in either a central or a lateral location produce a high partition efficiency of over 100 theoretical plates . Under the optimum operating conditions, the preparative capability of the countercurrent chromatograph was demonstrated on gram-scale separations of DNP-amino acids and dipeptides in a pair of multilayer coils connected in series with a total capacity of 1600 ml .