Correlation to predict heat transfer characteristics of a closed-end oscillating heat pipe at normal operating condition

โœ Scribed by S. Rittidech; P. Terdtoon; M. Murakami; P. Kamonpet; W. Jompakdee


Publisher
Elsevier Science
Year
2003
Tongue
English
Weight
186 KB
Volume
23
Category
Article
ISSN
1359-4311

No coin nor oath required. For personal study only.

โœฆ Synopsis


This paper describes the effect of dimensionless parameters on the characteristics of heat transfer in a closed-end oscillating heat pipe (CEOHP). The parameters studied in this paper are; (i) Bond numbers, (ii) Froude numbers, (iii) Weber numbers, (iv) Prandtl numbers and (v) Kutateladze numbers. Experiments were conducted to find out their effects on the heat transfer rates of copper CEOHPs with inner diameters of 0.66, 1.06 and 2.03 mm. The lengths of the evaporator, adiabatic and condenser sections were equal and changed to 15, 10 and 5 cm. The total lengths of the CEOHPs were 15, 10 and 5 m. R123, ethanol and water were used as the working fluids with a filling ratio of 50%. The evaporator was heated by hot water, while the condenser section was cooled by a solution of water and ethylene glycol with a 1:1 mixing ratio by volume. The angle of the CEOHPs used in the experiments was set at 0ยฐ(horizontal mode) with a controlled vapor temperature of 50 ยฐC. When the system reached the steady state, the temperature and the flow rate of the cooling substance was recorded in order to calculate the heat transfer rate of the CEOHP. It was found from the experiment that when R123 was used, the inner diameter affected the heat flux. The results of the experiment showed that when the inner diameter was larger, so was the heat flux. The result for ethanol showed the opposite; when the inner diameter increased, the heat flux decreased. Because of insufficient data obtain from using water as working fluid, the heat flux could not be reliably measured. The evaporator section lengths also affected the heat flux. The evaporator length of 15 cm gave the lowest value of heat flux. When the number of turns decreased, the heat flux increased and when n is equal to 14, heat flux is still increasing with an decrease in n. The results of the experiment also showed that the correlation equation could be used to predict the heat flux and that the operation map could predict the operational range and the inner diameter.


๐Ÿ“œ SIMILAR VOLUMES


Correlation to predict heat-transfer cha
โœ S. Rittidech; W. Srimuang ๐Ÿ“‚ Article ๐Ÿ“… 2010 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 364 KB

Experiments are conducted to determine the effect of dimensionless parameters on heat-transfer characteristics of a vertical flat thermosyphon (VFT). The VFT used in this study employed a copper tube with an inner diameter of 8.6 mm. The cross-sectional areas of the tube were reduced by pressing the

A correlation to predict heat-transfer r
โœ T. Parametthanuwat; S. Rittidech; A. Pattiya ๐Ÿ“‚ Article ๐Ÿ“… 2010 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 877 KB

The effect of using silver nanofluid (de ionized water mixed with silver nano and particles less than 100 nm) on the thermal characteristics of a two-phase closed thermosyphon in an operating state was investigated in this research. The thermosyphon was made with copper tubes with 7.5, 11.1 and 25.4

Prediction of vortex penetration depth a
โœ Kouji Shiina; Tsutomu Kawamura; Masaya Ohtsuka; Tadashi Mizuno; Masakazu Hisatsu ๐Ÿ“‚ Article ๐Ÿ“… 2006 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 924 KB

## Abstract In a branch pipe with one closed end, the cavity flow penetrates into the branch pipe from the main loop and a thermal boundary layer occurs because the cavity flow is a hot fluid, but heat removal causes a colder fluid in the branch pipe. This thermal stratification may affect the stru