𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Coronary MRA with 3D undersampled projection reconstruction TrueFISP

✍ Scribed by Andrew C. Larson; Orlando P. Simonetti; Debiao Li


Book ID
102952176
Publisher
John Wiley and Sons
Year
2002
Tongue
English
Weight
951 KB
Volume
48
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Undersampled projection reconstruction (PR) offers improved imaging efficiency allowing a relative tradeoff between signal‐to‐noise ratio (SNR) or streak artifact and the number of acquired k‐space views rather than the tradeoff between resolution or aliasing artifact and the number of acquired k‐space lines inherent to Fourier imaging techniques. TrueFISP (true fast imaging with steady state precession) is ideally suited for undersampled PR imaging because of its inherently high SNR. The purpose of this work was to investigate the feasibility of using undersampled three‐dimensional (3D) PR TrueFISP for breathhold coronary artery imaging. Phantom studies and a preliminary in vivo comparison demonstrated the improved spatial resolution of PR over Fourier TrueFISP with the same imaging time. In a 24‐heartbeat coronary imaging scheme, segmented 3D PR TrueFISP provided a 1.0 × 1.0 mm^2^ isotropic in‐plane voxel size while acquiring between 93 and 153 views per partition. Streak artifacts were present in some images but were not found to impede coronary artery delineation. In conclusion, 3D undersampled PR TrueFISP provides isotropic in‐plane voxel size within a single breathhold and is a promising technique for coronary artery imaging. Magn Reson Med 48:594–601, 2002. © 2002 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Myocardial wall tagging with undersample
✍ Dana C. Peters; Frederick H. Epstein; Elliot R. McVeigh 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 283 KB

## Abstract Azimuthally undersampled projection reconstruction (PR) acquisition is investigated for use in myocardial wall tagging with MR using grid tags to provide increased temporal and spatial resolution. PR can provide the high‐resolution images required for tagging with very few projections,

Time-resolved, undersampled projection r
✍ J. Du; T.J. Carroll; H.J. Wagner; K. Vigen; S.B. Fain; W.F. Block; F.R. Korosec; 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 753 KB

Imaging of the blood vessels below the knee using contrast-enhanced (CE) MRI is challenging due to the need to coordinate image acquisition and arrival of the contrast in the targeted vessels. Time-resolved acquisitions have been successful in consistently capturing images of the arterial phase of t

Free-breathing whole-heart coronary MRA
✍ C. Stehning; P. Börnert; K. Nehrke; H. Eggers; M. Stuber 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 305 KB

## Abstract Respiratory motion is a major source of artifacts in cardiac magnetic resonance imaging (MRI). Free‐breathing techniques with pencil‐beam navigators efficiently suppress respiratory motion and minimize the need for patient cooperation. However, the correlation between the measured navig

Navigator-gated free-breathing 3D balanc
✍ Elmar Spuentrup; Arno Buecker; Julius Meyer; Rolf W. Günther; Matthias Stuber 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 449 KB

## Abstract A cardiac‐triggered, free‐breathing, 3D balanced FFE projection renal MR angiography (MRA) technique with a 2D pencil beam aortic labeling pulse for selective aortic spin tagging was developed. For respiratory motion artifact suppression during free breathing, a prospective real‐time na