Contribution of oral magnetic particles in MR imaging of the abdomen with spin-echo and gradient-echo sequences
✍ Scribed by Frank P. Boudghëne; Torre Bach-Gansmo; Jean-Didier Grange; Samuel Lame; Christine Nantois; Claudy Wallays; Jean-Michel Bigot
- Publisher
- John Wiley and Sons
- Year
- 1993
- Tongue
- English
- Weight
- 688 KB
- Volume
- 3
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
An open phase III clinical trial of the oral contrast agent OMP (oral magnetic particles) was performed in 35 patients undergoing abdominal magnetic resonance (MR) imaging at 1.5 T with axial spin‐echo and gradient‐echo sequences. The diagnostic efficacy of OMP was examined by comparing pre‐ and postcontrast images. Bowel loops and abdominal organs were more easily recognizable after OMP ingestion, and the general quality of the images was improved because of fewer bowel‐related artifacts. The diagnostic value of the postcontrast abdominal MR examination was superior or equal to that of the precontrast study, and additional information was obtained in 44% of the cases. Postcontrast gradient‐echo sequences increased confidence in the MR examination in 18% of cases. OMP was well tolerated and increased the quality and amount of diagnostic information acquired during the examination. Gradient‐echo imaging was found to be a useful complement, but the need for a reduction in susceptibility artifacts was apparent and indicates that a decrease in TE or the use of rapid spin‐echo sequences might be advantageous.
📜 SIMILAR VOLUMES
In this paper we present a pulse sequence that combines a displacement-encoded stimulated echo with rapid sampling of k-space by means of turbo spin echo imaging. The stimulated echo enables the use of long observation times between the two pulsed field gradients that sample q-space completely. Prop
## Abstract To extend the signal longevity of magnetically excited spins in flowing fluids while in a state of global coherent free precession (GCFP), a refocusing radiofrequency (RF) pulse and bipolar gradient waveforms were combined with the GCFP sequence. The data demonstrate that RF refocusing
In 22 patients with a diverse range of thoracic abnormalities, T2-weighted magnetic resonance (MR) images of the chest were obtained with electrocardiograph (ECG)-triggered turbo spin-echo (TSE), ECG-triggered conventional spin-echo (CSE), and nontriggered TSE sequences, and the images were compared
## Abstract The purpose of this work was to validate in phantom studies and demonstrate the clinical feasibility of MR proton resonance frequency thermometry at 1.5 T with segmented gradient‐echo echo planar imaging (GRE‐EPI) sequences during liver tumour radiofrequency (RF) ablation. Classical GRE