The efficacy of the superparamagnetic contrast agent magnetic starch microspheres (MSM) was evaluated in vitro by NMR relaxometry and in vivo by MR imaging using T2-weighted spin-echo (SE) and turbo spin-echo (TSE) sequences at 0.5 T and 1.5 T in 60 normal rats who received MSM in doses of 10-50 mu
Contrast behavior and relaxation effects of conventional and hyperecho-turbo spin echo sequences at 1.5 and 3 T
✍ Scribed by Matthias Weigel; Juergen Hennig
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 428 KB
- Volume
- 55
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
To overcome specific absorption rate (SAR) limitations of spin‐echo‐based MR imaging techniques, especially at (ultra) high fields, rapid acquisition relaxation enhancement/TSE (turbo spin echo)/fast spin echo sequences in combination with constant or variable low flip angles such as hyperechoes and TRAPS (hyperTSE) have been introduced. Due to the multiple spin echo and stimulated echo pathways involved in the signal formation, the contrast behavior of such sequences depends on both T~2~ and T~1~ relaxation times. In this work, constant and various variable flip angle sequences were analyzed in a volunteer study. It is demonstrated that a single effective echo time parameter TE~eff~ can be calculated that accurately describes the overall T~2~ weighted image contrast. TE~eff~ can be determined by means of the extended phase graph concept and is practically independent of field strength. Using the described formalism, the contrast of any TSE sequence can be predicted. HyperTSE sequences are demonstrated to show a robust and well‐defined T~2~ contrast allowing clinical routine MRI to be performed with SAR reductions of typically at least 70%. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Magnetization transfer effects represent a major source of contrast in multislice turbo spin echo sequences (TSE)/fast spin echo sequences. Generally, low refocusing flip angles have become common in such MRI sequences, especially to mitigate specific absorption rate problems. Since the
To compare the clinical usefulness of T2-weighted breath-hold sequences for imaging the liver, 33 patients with 97 focal hepatic lesions were studied with a 1.0-T scanner by using T2-weighted breath-hold turbo spin-echo (SE) sequences and T2-weighted breath-hold half-Fourier single-shot turbo SE (HA
## Abstract The aim was to investigate the effects of echo time (TE) on diffusion quantification of brain white matter. Seven rhesus monkeys (all males; age, 4–6 years; weight, 5–7 kg) underwent diffusion tensor imaging (DTI) with a series of TEs in 1.5T and 3.0T MR scanners. The mean diffusivity (
## Abstract ## Purpose To compare 3.0T and 1.5T MR systems in terms of the effect of superparamagnetic iron oxide (SPIO) on tumor‐to‐liver contrast in T2\*‐weighted gradient‐echo MRI. ## Materials and Methods SPIO‐enhanced gradient‐echo MR images of the liver with four different TEs (3, 5.3, 6.5