𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Continuous-flow method for the determination of total trihalomethane formation potential in waters

✍ Scribed by Toyoaki Aoki; Kouji Kawakami


Publisher
Elsevier Science
Year
1992
Tongue
English
Weight
336 KB
Volume
261
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


A double-tube separation system with an Inner tube of nucroporous PTFE and an outer tube of PTFE IS proposed for the contmuous determmatlon of tnhalomethanes (THMs) m waters The THMs m the sample, after reactlon unth sodium hypochlonte solution at 98°C and reducmg the residual hypochlonte with sodium sulphlte, are separated wth the double-tube system at 50°C They are then mured mth alkaline mcotmannde solution and heated at 98°C After coolmg m an ice-bath, the reaction product IS fed to a spectrofluoruneter and the emwlon of fluorescence excited at 372 nm IS measured at 467 nm The response was obtamed wrlthm 20 mm The detection hnut (signal-to-noise ratio = 3) was 2 2 kg I-' The total THM formation potential obtamed by the present method for lake and river waters were m good agreement vvlth those obtamed by the Japanese standard batch method


📜 SIMILAR VOLUMES


Continuous-flow method for the determina
✍ Toyoaki Aoki; Yoshiko Fujimaru; Yuko Oka; Kimiko Fujie 📂 Article 📅 1993 🏛 Elsevier Science 🌐 English ⚖ 454 KB

A double-tube separation system with an inner tube of microporous PTFE and an outer tube of PTFE is proposed for the continuous determination of total inorganic carbonate (TIC) in natural waters. Carbon dioxide produced by mixing a sample with 0.5 M sulphuric acid in the outer tube permeates through

Methods validation for the determination
✍ Monica Culea; Onuc Cozar; Dumitru Ristoiu 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 100 KB 👁 1 views

## Abstract Trihalomethanes (THMs), chlorinated by‐products in drinking water, have been determined by comparing some analytical methods, based on the following techniques: liquid–liquid extraction‐gas chromatography‐mass spectrometry (LLE‐GC‐MS), headspace‐gas chromatography‐mass spectrometry (hea

Flow Injection Method for Preconcentrati
✍ Pablo Richter; M. Inés Toral; Pablo Jaque 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 81 KB 👁 2 views

The analytical application of a simple polarographic ¯ow through cell, which was previously designed for the continuous polarographic analysis of organic compounds in pharmaceuticals and urine, is proposed in this work for the determination of copper in diluted water samples. The cell contains a con