A double-tube separation system with an Inner tube of nucroporous PTFE and an outer tube of PTFE IS proposed for the contmuous determmatlon of tnhalomethanes (THMs) m waters The THMs m the sample, after reactlon unth sodium hypochlonte solution at 98°C and reducmg the residual hypochlonte with sodiu
Continuous-flow method for the determination of total inorganic carbonate in water
✍ Scribed by Toyoaki Aoki; Yoshiko Fujimaru; Yuko Oka; Kimiko Fujie
- Publisher
- Elsevier Science
- Year
- 1993
- Tongue
- English
- Weight
- 454 KB
- Volume
- 284
- Category
- Article
- ISSN
- 0003-2670
No coin nor oath required. For personal study only.
✦ Synopsis
A double-tube separation system with an inner tube of microporous PTFE and an outer tube of PTFE is proposed for the continuous determination of total inorganic carbonate (TIC) in natural waters. Carbon dioxide produced by mixing a sample with 0.5 M sulphuric acid in the outer tube permeates through the microporous PTFE wall and dissolved in 5 mM sodium hydroxide solution in the inner tube. The inner stream passes two electrical conductivity (EC) detectors, one before and the other after the double-tube separator, and TIC in the sample is measured as the difference in the signals obtained from the two detectors. The relative electrical conductivity was proportional to the concentration of TIC in the range 5 x lo-'-5 X lo-' M. The limit of detection (signal-to-noise ratio = 3) was 1.0 X 10e5 M. The time required for a 98% response was 2 min. Sulphide interfered but was completely decomposed by using chromate. The method was applied to the determination of TIC in lake waters.
📜 SIMILAR VOLUMES
The analytical application of a simple polarographic ¯ow through cell, which was previously designed for the continuous polarographic analysis of organic compounds in pharmaceuticals and urine, is proposed in this work for the determination of copper in diluted water samples. The cell contains a con
## Abstract Trihalomethanes (THMs), chlorinated by‐products in drinking water, have been determined by comparing some analytical methods, based on the following techniques: liquid–liquid extraction‐gas chromatography‐mass spectrometry (LLE‐GC‐MS), headspace‐gas chromatography‐mass spectrometry (hea
A voltammetric method of Cr(VI) determination in a flow system based on the combination of selective accumulation of the product of Cr(VI) reduction on hanging mercury drop electrode and a very sensitive method of chromium determination in the presence of cupferron previously described is proposed.