𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Contact angles of pharmaceutical powders

✍ Scribed by C. F. Lerk; M. Lagas; J. P. Boelstra; P. Broersma


Publisher
John Wiley and Sons
Year
1977
Tongue
English
Weight
204 KB
Volume
66
Category
Article
ISSN
0022-3549

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


Water adsorption kinetics and contact an
✍ Tim H. Muster; Clive A. Prestidge πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 171 KB

Water sorption kinetics and water contact angles have been characterized for a range of pharmaceutical powders: ambroxol hydrochloride, griseofulvin, N,n-octyl-D-gluconamide, paracetamol, sulfathiazole, and theophylline. The uptake of water by powder samples at saturated vapor pressure was modeled u

Dynamic contact angles
✍ E. B. Gutoff; C. E. Kendrick πŸ“‚ Article πŸ“… 1982 πŸ› American Institute of Chemical Engineers 🌐 English βš– 744 KB

## Abstract The dynamic contact angles of various liquids on a gelatin‐subbed polyester tape were investigated by plunging a tape into a pool of liquid, in the manner of Perry and of Burley and Kennedy. The effect of the upper fluid was studied by replacing the air normally present by immiscible oi

Prediction of contact angle for pharmace
✍ Eero Suihko; Robert T. Forbes; Ossi Korhonen; Jarkko Ketolainen; Petteri Paronen πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 243 KB

Three methods for modeling and predicting water contact angle for a heterogeneous series of pharmaceuticals using computed molecular descriptors and statistical analysis were developed. A number of theoretical molecular descriptors that were related to the structure and physicochemical properties we

Dynamic Cycling Contact Angle Measuremen
✍ C.N.C. Lam; R.H.Y. Ko; L.M.Y. Yu; A. Ng; D. Li; M.L. Hair; A.W. Neumann πŸ“‚ Article πŸ“… 2001 πŸ› Elsevier Science 🌐 English βš– 286 KB

Dynamic cycling contact angle (DCCA) measurements of six liquids from two homologous series (i.e., alkanes and alcohols) on FC-732-coated silicon wafer surfaces were performed using automated axisymmetric drop shape analysis-profile (ADSA-P). Unlike the previous one-cycle measurements that have been

Contact angles and wettability of human
✍ Hans Schott πŸ“‚ Article πŸ“… 1971 πŸ› John Wiley and Sons 🌐 English βš– 388 KB

The contact angles of several liquids on human skin were measured before and after extraction of surface lipids with acetone. The critical surface tension of the skin was determined by extrapolating the cosines of the contact angles of the liquids as a function of their surface tensions to unity. Th