𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Comparison of T2*-weighted sequences for functional MRI

✍ Scribed by Xiaoping Hu; Peter Erhard; Tuang Huu Le; Seong-Gi Kim; Ravi Menon; Peter Andersen; Gregor Adriany; John P. Strupp; Kâmil Uǧurbil


Publisher
John Wiley and Sons
Year
1995
Tongue
English
Weight
691 KB
Volume
6
Category
Article
ISSN
0899-9457

No coin nor oath required. For personal study only.

✦ Synopsis


Several sequences, including conventional gradient-echo sequence (e.g., FLASH), gradient-echo echo-planar imaging (EPI), T; prepared ultrafast gradient echo technique (TurboFLASH), and T;-weighted spiral sequence, are currently used for T;-weighted functional magnetic resonance imaging. This paper presents a comparison of FLASH, gradient-echo EPI, and T;-prepared TurboFLASH. Experimental results have demonstrated that these sequences have different susceptibility to physiologic fluctuation, which is likely the dominant source of noise. EPI images exhibit the lowest relative fluctuation, while images obtained by FLASH and TurboFLASH, respectively, display similar relative fluctuation. Functional maps generated using these sequences are comparable but exhibit different sensitivity to activation from large vessels. Consequently, interpretation of activation results from various maps should take into account the difference in the sequences. 0 1995 John Wiley 8 Sons, inc.


📜 SIMILAR VOLUMES


Comparison of multishot turbo spin echo
✍ Jeong-Sik Yu; Ki Whang Kim; Young Hwan Kim; Eun-Kee Jeong; Daisy Chien 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 781 KB

The purpose of this study was to compare the relative usefulness of multishot turbo spin echo (TSE) and half-Fourier single-shot turbo spin echo (HASTE) for determination of optimal breath-hold fast T2-weighted technique in terms of lesion detection, lesion-to-liver contrast-to-noise ratio (CNR), an

Ultrafast Perfusion-Weighted MRI of Func
✍ Christian M. Kerskens; Mathias Hoehn-Berlage; Bernd Schmitz; Elmar Busch; Christ 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 426 KB 👁 1 views

A fast version of the arterial spin tagging technique for the detection of cerebral perfusion is presented. Based on adiabatic spin inversion in combination with snapshot FLASH imaging, our technique allows the recording of perfusion changes with a temporal resolution of about 3 s. Differences of ce

Pulse sequence for multislice T1ρ-weight
✍ Andrew J. Wheaton; Arijitt Borthakur; Sridhar R. Charagundla; Ravinder Reddy 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 234 KB

## Abstract A 2D multislice spin‐lock (MS‐SL) MR pulse sequence is presented for rapid volumetric __T__~1ρ~‐weighted imaging. Image quality is compared with __T__~1ρ~‐weighted data collected using a single‐slice (SS) SL sequence and __T__~2~‐weighted data from a standard MS spin‐echo (SE) sequence.

Hepatic T2-weighted MRI: A prospective c
✍ G. Glenn Coates; Joseph A. Borrello; Elizabeth G. McFarland; Scott A. Mirowitz; 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 980 KB

## Abstract The purpose of this study was to quantitatively compare the hepatic contrast characteristics of conventional spin‐echo (CSE) and fast spin‐echo (FSE) sequences with breath‐hold T2‐weighted images acquired with half‐Fourier turbo spin echo (HASTE). Forty‐five patients were examined with

Comparison of breath-hold multishot echo
✍ Koichiro Yamakado; Hajime Sakuma; Shuichi Murashima; Atsuhiro Nakatsuka; Kaname 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 777 KB

## Abstract The purpose of this study was to evaluate the usefulness of multishot echo‐planar imaging in detecting liver tumors in comparison with respiratory triggered T2‐weighted fast‐spin‐echo (FSE) imaging. Thirty‐two patients with 70 focal liver lesions were imaged using a 1.5‐T high speed MR

Assessment of relative brain iron concen
✍ Roger J. Ordidge; Jay M. Gorell; Jean C. Deniau; Robert A. Knight; Joseph A. Hel 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 794 KB

## Abstract In this paper a new method is presented for the relative assessment of brain iron concentrations based on the evaluation of T~2~ and T~2~\* ‐weighted images. A multiecho sequence is employed for rapid measurement of T~2~ and T~2~\*, enabling calculation of the line broadening effect ( T