The purpose of this study was to compare the relative usefulness of multishot turbo spin echo (TSE) and half-Fourier single-shot turbo spin echo (HASTE) for determination of optimal breath-hold fast T2-weighted technique in terms of lesion detection, lesion-to-liver contrast-to-noise ratio (CNR), an
Comparison of T2*-weighted sequences for functional MRI
✍ Scribed by Xiaoping Hu; Peter Erhard; Tuang Huu Le; Seong-Gi Kim; Ravi Menon; Peter Andersen; Gregor Adriany; John P. Strupp; Kâmil Uǧurbil
- Publisher
- John Wiley and Sons
- Year
- 1995
- Tongue
- English
- Weight
- 691 KB
- Volume
- 6
- Category
- Article
- ISSN
- 0899-9457
No coin nor oath required. For personal study only.
✦ Synopsis
Several sequences, including conventional gradient-echo sequence (e.g., FLASH), gradient-echo echo-planar imaging (EPI), T; prepared ultrafast gradient echo technique (TurboFLASH), and T;-weighted spiral sequence, are currently used for T;-weighted functional magnetic resonance imaging. This paper presents a comparison of FLASH, gradient-echo EPI, and T;-prepared TurboFLASH. Experimental results have demonstrated that these sequences have different susceptibility to physiologic fluctuation, which is likely the dominant source of noise. EPI images exhibit the lowest relative fluctuation, while images obtained by FLASH and TurboFLASH, respectively, display similar relative fluctuation. Functional maps generated using these sequences are comparable but exhibit different sensitivity to activation from large vessels. Consequently, interpretation of activation results from various maps should take into account the difference in the sequences. 0 1995 John Wiley 8 Sons, inc.
📜 SIMILAR VOLUMES
A fast version of the arterial spin tagging technique for the detection of cerebral perfusion is presented. Based on adiabatic spin inversion in combination with snapshot FLASH imaging, our technique allows the recording of perfusion changes with a temporal resolution of about 3 s. Differences of ce
## Abstract A 2D multislice spin‐lock (MS‐SL) MR pulse sequence is presented for rapid volumetric __T__~1ρ~‐weighted imaging. Image quality is compared with __T__~1ρ~‐weighted data collected using a single‐slice (SS) SL sequence and __T__~2~‐weighted data from a standard MS spin‐echo (SE) sequence.
## Abstract The purpose of this study was to quantitatively compare the hepatic contrast characteristics of conventional spin‐echo (CSE) and fast spin‐echo (FSE) sequences with breath‐hold T2‐weighted images acquired with half‐Fourier turbo spin echo (HASTE). Forty‐five patients were examined with
## Abstract The purpose of this study was to evaluate the usefulness of multishot echo‐planar imaging in detecting liver tumors in comparison with respiratory triggered T2‐weighted fast‐spin‐echo (FSE) imaging. Thirty‐two patients with 70 focal liver lesions were imaged using a 1.5‐T high speed MR
## Abstract In this paper a new method is presented for the relative assessment of brain iron concentrations based on the evaluation of T~2~ and T~2~\* ‐weighted images. A multiecho sequence is employed for rapid measurement of T~2~ and T~2~\*, enabling calculation of the line broadening effect ( T