Comparison of T1 and T2 metabolite relaxation times in glioma and normal brain at 3T
✍ Scribed by Yan Li; Radhika Srinivasan; Helene Ratiney; Ying Lu; Susan M. Chang; Sarah J. Nelson
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 549 KB
- Volume
- 28
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To measure T~1~ and T~2~ relaxation times of metabolites in glioma patients at 3T and to investigate how these values influence the observed metabolite levels.
Materials and Methods
A total of 23 patients with gliomas and 10 volunteers were studied with single‐voxel two‐dimensional (2D) J‐resolved point‐resolved spectral selection (PRESS) using a 3T MR scanner. Voxels were chosen in normal appearing white matter (WM) and in regions of tumor. The T~1~ and T~2~ of choline containing compounds (Cho), creatine (Cr), and N‐acetyl aspartate (NAA) were estimated.
Results
Metabolite T~1~ relaxation values in gliomas were not significantly different from values in normal WM. The T~2~ of Cho and Cr were statistically significantly longer for grade 4 gliomas than for normal WM but the T~2~ of NAA was similar. These differences were large enough to impact the corrections of metabolite levels for relaxation times with tumor grade in terms of metabolite ratios (P < 0.001).
Conclusion
The differential increase in T~2~ for Cho and Cr relative to NAA means that the ratios of Cho/NAA and Cr/NAA are higher in tumor at longer echo times (TEs) relative to values in normal appearing brain. Having this information may be useful in defining the acquisition parameters for optimizing contrast between tumor and normal tissue in MR spectroscopic imaging (MRSI) data, in which limited time is available and only one TE can be used. J. Magn. Reson. Imaging 2008;28:342–350. © 2008 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To measure ^1^H relaxation times of cerebral metabolites at 3 T and to investigate regional variations within the brain. ## Materials and Methods Investigations were performed on a 3.0‐T clinical whole‐body magnetic resonance (MR) system. T2 relaxation times of N‐acetyl as
## Abstract Although recent studies indicate that use of a single global transverse relaxation time, __T__~__2__~, per metabolite is sufficient for better than ±10% quantification precision at intermediate and short echo‐time spectroscopy in young adults, the age‐dependence of this finding is unkno
## Abstract T~1~, T~2~, and magnetization transfer (MT) measurements were performed in vitro at 3 T and 37°C on a variety of tissues: mouse liver, muscle, and heart; rat spinal cord and kidney; bovine optic nerve, cartilage, and white and gray matter; and human blood. The MR parameters were compare
## Abstract The transverse relaxation times, __T__~2~, of __N__‐acetylaspartate (NAA), total choline (Cho), and creatine (Cr) obtained at 3T in several human brain regions of eight healthy volunteers are reported. They were obtained simultaneously in 320 voxels with three‐dimensional (3D) proton MR