𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Comparison of on-column and splitless injection in capillary gas chromatography coupled with atomic emission detection

✍ Scribed by Pedersen-Bjergaard, Stig ;Semb, Svein Ingar ;Brevik, Einar Magne


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
346 KB
Volume
20
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


A new configuration for coupling purge-a
✍ Liu, Shili ;Kang, Jiangshi ;Strother, Dennis L. ;Carley, Robert J. ;Stuart, Jame πŸ“‚ Article πŸ“… 1989 πŸ› John Wiley and Sons 🌐 English βš– 470 KB πŸ‘ 1 views

A new configuration for coupling a purge-and-trap unit to a capillary column gas chromatograph via a cryogenic focusing interface has been developed. In this configuration, the precolumn of the cryogenic focusing interface was inserted through the septum of a split/splitless injection port where it

Capillary gas-liquid chromatography of b
✍ Kariaganis, Georg ;Paumgartner, Gustav πŸ“‚ Article πŸ“… 1978 πŸ› John Wiley and Sons 🌐 English βš– 195 KB πŸ‘ 1 views

## Abstract Analysis of trimethylsilylethers of methyl esters of bile acids exhibits high separation efficiency with a 20 m Γ— 0.3 mm glass capillary column covered with a crystal layer of barium carbonate and coated with polyethyleneglycol 20000 as liquid phase [3]. The sensitivity and reproducibil

Analysis of antiepileptic drugs by capil
✍ Volmut, Juraj ;MelnΓ­k, Miloslav ;MatisovΓ‘, Eva πŸ“‚ Article πŸ“… 1993 πŸ› John Wiley and Sons 🌐 English βš– 319 KB πŸ‘ 1 views

## Abstract A simple and quick gas chromatographic method has been developed for the determination of up to six commonly used antiepileptic drugs in human serum. The antiepileptics are isolated from serum by solid phase extraction on to a reversed phase sorbent and recovered with ethyl acetate as e

Evaluation of automated and manual hot-s
✍ Stan, H.-J. ;MΓΌller, H.-M. πŸ“‚ Article πŸ“… 1988 πŸ› John Wiley and Sons 🌐 English βš– 371 KB πŸ‘ 1 views

Three different injection modes were compared for the analysis of organophosphorus pesticides. Differing results were found for several compounds depending on their chemical structure and thermostability. The programmed temperature vaporizing injector used in this study seemed to be the most promisi

Determination of the volatiles from toba
✍ Gang Li; Da Wu; Ye Wang; Wenyan Xie; Xiangmin Zhang; Baizhan Liu πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 195 KB

## Abstract A new gas chromatograph‐atomic emission detector (GC‐AED) coupled with Deans switching technique for analyzing volatiles from tobaccos were developed. The detector operating parameters (reagent gas pressure and make‐up gas flow rate) were optimized. The detection limits for the elements