## Abstract ## Purpose To compare gadoxetic acid disodium (Gd‐EOB‐DTPA)‐enhanced magnetic resonance imaging (MRI) with gadobenate dimeglumine (Gd‐BOPTA)‐enhanced MRI in preoperative living liver donors for the evaluation of vascular and biliary variations. ## Materials and Methods Sixty‐two livi
Comparison of gadoxetic acid-enhanced dynamic imaging and diffusion-weighted imaging for the preoperative evaluation of colorectal liver metastases
✍ Scribed by Woo-Suk Chung; Myeong-Jin Kim; Yong Eun Chung; Yeo-Eun Kim; Mi-Suk Park; Jin-Young Choi; Ki Whang Kim
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 460 KB
- Volume
- 34
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose:
To retrospectively compare the diagnostic accuracy for the detection of colorectal liver metastases between gadoxetic acid‐enhanced MRI (EOB‐MRI) and diffusion‐weighted imaging (DWI) on 3.0 Tesla (T) system, and then to determine whether a combination of the two techniques may improve the diagnostic performance.
Materials and Methods:
Forty‐seven patients underwent MR imaging at 3.0T, including DWI (DWI set) and dynamic and hepatobiliary phase EOB‐MRI (EOB set) for the preoperative evaluation of colorectal liver metastases. All suspicious metastases were confirmed by hepatic surgery. Two blinded readers independently reviewed three different image sets, which consisted of DWI set, EOB set, and combined set. The accuracy was assessed by the area (Az) under the alternative‐free response receiver operating characteristic curve, and the sensitivity and positive predictive value (PPV) were calculated.
Results:
We found a total of 78 confirmed colorectal liver metastases in 42 of 47 patients. Each reader noted higher diagnostic accuracy of combined set of EOB‐MRI and DWI than DWI set and EOB set, without statistical significance. Regardless of the size of colorectal liver metastasis, each reader detected significantly more metastases on combined set than on DWI set, and PPV was significantly higher with DWI set than with EOB set or with combined set for one reader.
Conclusion:
EOB‐MRI was more useful for the detection of colorectal liver metastases, while DWI was more useful for their characterization. The combination of EOB‐MRI and DWI showed significantly higher accuracy and sensitivity for the preoperative detection of small colorectal liver metastases than DWI. J. Magn. Reson. Imaging 2011;. © 2011 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Purpose: To compare the accuracy of fluoro-18-deoxyglucose positron emission tomography (fdg-pet) and dynamic-enhanced magnetic resonance imaging (mri) scans in the diagnosis of liver metastatic lesions from colon and other sources. ## Materials and methods: Thirty consecutive patients with kn
## Abstract ## Purpose To study the recognition of malignant lesions of the liver on diffusion‐weighted images (DWI) can be improved by the administration of superparamagnetic iron oxide (SPIO). ## Materials and Methods Pre‐ and post‐SPIO mediated DWI of the liver was compared in six patients wi
## Abstract ## Purpose: To assess the value of hepatobiliary phase gadoxetic acid (EOB)‐enhanced magnetic resonance imaging (MRI) for the diagnosis of early stage hepatocellular carcinoma (HCC) (<3 cm) compared to triple‐phase dynamic multidetector computed tomography (MDCT). ## Materials and Met
## Abstract ## Purpose: To compare the diagnostic accuracy of superparamagnetic iron oxide (SPIO)‐enhanced fluid‐attenuated inversion‐recovery echo‐planar imaging (FLAIR EPI) for malignant liver tumors with that of T2‐weighted turbo spin‐echo (TSE), T2\*‐weighted gradient‐echo (GRE), and diffusion