๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Comparison of eddy-covariance measurements of CO2fluxes by open- and closed-path CO2analysers

โœ Scribed by R. Leuning; K. M. King


Publisher
Springer
Year
1992
Tongue
English
Weight
918 KB
Volume
59
Category
Article
ISSN
0006-8314

No coin nor oath required. For personal study only.

โœฆ Synopsis


Eddy fluxes of CO2 estimated using a sonic anemometer and a closed-path analyser were, on average, 16% lower than those obtained with the same anemometer and an adjacent open-path CO1 analyser. Covariances between vertical windspeed and CO2 density from the closed-path analyser were calculated using data points for CO2 that were delayed relative to anemometer data by the time required for a parcel of air to travel from the tube inlet to the CO2 sensor. Air flow in the intake tube was laminar. Densities of CO2 that had been corrected for spurious fluctuations arising from fluctuations in temperature and humidity were used in the flux calculations. Corrections for the cross-sensitivity of CO2 analysers to water vapour were also incorporated. Spectral analysis of the corrected CO2 signal from the closed-path analyser showed that damping of fluctuations in the sampling tube at frequencies f> 0.1 Hz caused the apparent loss in flux. The measured losses can be predicted accurately using theory that describes the damping of oscillations in a sampling tube. High-frequency response of the closed-path system can be improved substantially by ensuring turbulent flow in the tube, using a combination of high volumetric flow rate and small tube diameter. The analysis of attenuation of turbulent fluctuations in flow through tubes is applicable to the measurement of fluxes of other minor atmospheric constituents using the eddy covariance method.


๐Ÿ“œ SIMILAR VOLUMES


Eddy-covariance CO2flux measurements usi
โœ R. Leuning; J. Moncrieff ๐Ÿ“‚ Article ๐Ÿ“… 1990 ๐Ÿ› Springer ๐ŸŒ English โš– 831 KB

Methods of calibrating infrared CO2 analysers for sensitivity to CO2 and water vapour are described. Equations to correct eddy covariance CO2 flux measurements are presented for: (i) analyser cross-sensitivity to water vapour and the effects of density fluctuations arising from atmospheric fluxes of

Eddy-covariance CO2flux measurements usi
๐Ÿ“‚ Article ๐Ÿ“… 1991 ๐Ÿ› Springer ๐ŸŒ English โš– 26 KB

The axis labels in Figure on p. 71 were interchanged, i.e., the y-axis should be H and the x-axis should be hE. As a result, the sentence beginning on line 6, p. 72 should read: Flux corrections increase with hE at any value of H for an analyser insensitive to water vapour (Figure ), whereas they d

Effects of heat and water vapor transpor
โœ R. Leuning; O. T. Denmead; A. R. G. Lang; E. Ohtaki ๐Ÿ“‚ Article ๐Ÿ“… 1982 ๐Ÿ› Springer ๐ŸŒ English โš– 889 KB

Flux densities of carbon dioxide were measured over an arid, vegetation-free surface by eddy covariance techniques and by a heat budget-profile method, in which CO\* concentration gradients were specified in terms ofmixing ratios. This method showed negligible fluxes ofCO,, consistent with the baren

Eddy correlation measurements of CO2, la
โœ Dean E. Anderson; Shashi B. Verma; Norman J. Rosenberg ๐Ÿ“‚ Article ๐Ÿ“… 1984 ๐Ÿ› Springer ๐ŸŒ English โš– 556 KB

Eddy correlation equipment was used to measure mass and energy fluxes over a soybean crop. A rapid response CO, sensor, a drag anemometer, a Lyman-alpha hygrometer and a fine wire thermocouple were used to sense the fluctuating quantities. Diurnal fluxes of sensible heat, latent heat and CO, were c