𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Comparison of chaotropic salt and ionic liquid as mobile phase additives in reversed-phase high-performance liquid chromatography of biogenic amines

✍ Scribed by Jolanta Flieger; Anna Czajkowska-Żelazko


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
304 KB
Volume
34
Category
Article
ISSN
1615-9306

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Highly hydrophilic compounds belonging to biogenic amines were analysed in the reversed‐phase system, modified with the addition of ionic liquids: 1‐ethyl‐3‐methyl‐imidazolium hexafluorophosphate (EMIM PF~6~) and chaotropic salt NaPF~6~ on Discovery HS C18 column at acidic conditions. The effect of the additives concentration and the presence of organic solvent on the analytes' chromatographic parameters such as retention factor, tailing factor and theoretical plates number were all determined. On the basis of k versus ionic liquid concentration in aqueous–organic mobile phase with constant amount of phosphate buffer, retention mechanism was studied. It was established that the presence of organic solvent with low dielectric constant and ionic liquid with both chaotropic ions allows achieving typical Langmuir shape of this relationship. Investigated mobile phase additives are comparable according to efficiency and selectivity towards biogenic amines analysis. However, the sensitivity was found to be better for the eluent system modified with chaotropic salt.


📜 SIMILAR VOLUMES


Ionic liquids as mobile phase additives
✍ Xialin Hu; Jinfeng Peng; Yuanjian Huang; Daqiang Yin; Jingfu Liu 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 264 KB

In this present study, 1-butyl-3-methylimidazolium chloride ([C 4 MIM]Cl), 1-octyl-3methylimidazolium chloride ([C 8 MIM]Cl), and 1-decyl-3-methylimidazolium chloride ([C 10 MIM]Cl) were adopted as mobile phase additives in the high performance liquid chromatography (HPLC) to simultaneously separate

Chromatographic performance of deuterate
✍ Jinno, K. 📂 Article 📅 1982 🏛 John Wiley and Sons 🌐 English ⚖ 252 KB 👁 1 views

The chromatographic performance of the deuterated solvents, CD30D and D20, has been investigated in reversed-phase micro high performance liquid chromatography. The chrornatographic performanceof CD30D is only slightlysuperior to that of CH30H. However, the performance of D20 is significantly superi

Reversed-phase liquid chromatographic se
✍ Ramisetti Nageswara Rao; Bondigalla Ramachandra; Rajavarapu Mastan Vali 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 292 KB

## Abstract The use of 3‐methylimidazolium cation‐based ionic liquids (ILs) was evaluated as mobile phase additives for separation of antiretroviral drugs on a monolithic column by RP‐HPLC. Separation of eight commonly used antiretroviral drugs was achieved on a Chromolith Flash, RP‐18e column (25×