The interface shear strength of uncoated Ti-6A1-4V, dense sintered hydroxyapatite (HA), and HA-coated Ti-6A1-4V were compared. Interface shear strength was determined using a transcortical push-out model in dogs 4 and 12 weeks after implantation. The interface shear strength of dense sintered HA and
Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants
โ Scribed by Inadome, T. ;Hayashi, K. ;Nakashima, Y. ;Tsumura, H. ;Sugioka, Y.
- Publisher
- John Wiley and Sons
- Year
- 1995
- Tongue
- English
- Weight
- 691 KB
- Volume
- 29
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
โฆ Synopsis
We performed a transcortical push-out test to determine the effect of surface roughness of hydroxyapatite (HA)coated implants on bone-implant shear strength in a canine model. Hydroxyapatite-and alumina-coated SUS316L with the same surface roughness (roughness average: Ra = 5 pm) and HA-coated Ti-6A1-4V (Ra = 8.4 pm), sintered HA (Ra = 0.9 pm), and dense alumina (Ra = 1.3 pm) were inserted into the dog's femur. The interface shear strength of the dense alumina was significantly lower than that of other implants at both 4 and 12 weeks after implantation. At 4 weeks after implantation, the interface shear strength of the alumina-coated SUS316L was significantly lower than that of other implants (P < .05) except the dense a h -mina, but at 12 weeks, there was no significant difference between the implant types except the dense alumina. This indicates that the surface roughness of the HA coating affects the enhancement of the bone-implant interface shear strength at the early period after implantation, and that a surface roughness of several micrometers does not influence the bond strength between bone and HA. A scanning electron microscopic study indicated that in almost all cases at 12 weeks, the failure site after push-out testing was the coating-substrate interface, not the coating-bone interface. Therefore, protection of the coating-substrate interface from direct shear loading is needed.
๐ SIMILAR VOLUMES
The effect of a plasma-sprayed hydroxylapatite (HA) coating on the degree of bone ingrowth and interface shear attachment strength was investigated using a canine femoral transcortical implant modeI. Cylindrical implants were fabricated by sintering spherical Co-Cr-Mo particles 500-710 p m in diamet
## Abstract We evaluated bone microhardness at the interface with hydroxyapatiteโcoated stainlessโsteel pins used in an external fracture fixation system. Pins were transversally inserted into the diaphyses of sheep tibiae and were loaded in for 6 weeks. Uncoated pins were implanted as controls. Mi
## Abstract A canine study was performed to make a histological and biomechanical evaluation of the interface between bone and two different bioceramic implants. A newly developed glassโceramic formed by P~2~O~5~, CaO, SiO~2~, and Al~2~O~3~, giving a crystal phase composed of CaP~2~O~6~๏ฃฟAlPO~4~๏ฃฟSiP
Tensile strength testing of the interface between bone and a plasma-sprayed hydroxyapatite (HA) coating-Ti-6Al-4V (implant I) and an HA coating-Ti (implant II) was performed. The bone-implant interface and tensile failure mode were evaluated by light microscopy (LM), SEM-energy dispersive X-ray anal