✦ Synopsis


Abstract

Purpose

To compare and determine the reproducibility of apparent diffusion coefficient (ADC) measurements of the normal liver parenchyma in breathhold, respiratory triggered, and free‐breathing diffusion‐weighted magnetic resonance imaging (DWI).

Materials and Methods

Eleven healthy volunteers underwent three series of DWI. Each DWI series consisted of one breathhold, one respiratory triggered, and two free‐breathing (thick and thin slice acquisition) scans of the liver, at b‐values of 0 and 500 s/mm^2^. ADCs of the liver parenchyma were compared by using nonparametric tests. Reproducibility was assessed by the Bland–Altman method.

Results

Mean ADCs (in 10^−3^ mm^2^/sec) in respiratory triggered DWI (2.07–2.27) were significantly higher than mean ADCs in breathhold DWI (1.57–1.62), thick slice free‐breathing DWI (1.62–1.65), and thin slice free‐breathing DWI (1.57–1.66) (P < 0.005). Ranges of mean difference in ADC measurement ± limits of agreement between two scans were −0.02–0.05 ± 0.16–0.24 in breathhold DWI, −0.14–0.20 ± 0.59–0.60 in respiratory triggered DWI, −0.03–0.03 ± 0.20–0.29 in thick slice free‐breathing DWI, and −0.01–0.09 ± 0.21–0.29 in thin slice free‐breathing DWI.

Conclusion

ADC measurements of the normal liver parenchyma in respiratory triggered DWI are significantly higher and less reproducible than in breathhold and free‐breathing DWI. J. Magn. Reson. Imaging 2008;28:1141–1148. © 2008 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Diffusion-weighted imaging of the liver:
✍ Bachir Taouli; Alison Sandberg; Alto Stemmer; Tejas Parikh; Samson Wong; Jian Xu 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 460 KB

## Purpose: To compare a free breathing navigator triggered single shot echoplanar imaging (ss epi) diffusion-weighted imaging (dwi) sequence with prospective acquisition correction (pace) with a breathhold (bh) dwi sequence for liver imaging. ## Materials and methods: Thirty-four patients were e

High-resolution MR-imaging of the liver
✍ Christoph J. Zech; Karin A. Herrmann; Armin Huber; Olaf Dietrich; Alto Stemmer; 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 533 KB

## Abstract ## Purpose To compare high‐resolution T2‐weigthed images of the liver with and without integrated parallel acquisition techniques (iPAT) using either breath‐hold sequences in combination with prospective acquisition motion correction (PACE) or respiratory triggering. ## Materials and

Image quality and focal lesion detection
✍ Seung Soo Lee; Jae Ho Byun; Hye-Suk Hong; Seong Ho Park; Hyung Jin Won; Yong Moo 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 359 KB

## Abstract ## Purpose To evaluate image quality and accuracy for the detection of focal hepatic lesions depicted on T2‐weighted images obtained with two high‐resolution free‐breathing techniques (navigator‐triggered turbo spin‐echo [TSE] and respiratory‐triggered TSE) and two standard‐resolution