## Abstract Respiratory viral infections are one of the leading causes of morbidity and mortality, particularly in children, the elderly and immunocompromised persons. Rapid identification of viral etiology is critical in ruling out non‐viral infections, initiating antiviral treatment and limiting
Comparative evaluation of the seegene seeplex RV15 and real-time PCR for respiratory virus detection
✍ Scribed by David F. Bibby; Iain McElarney; Judith Breuer; Duncan A. Clark
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 118 KB
- Volume
- 83
- Category
- Article
- ISSN
- 0146-6615
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Respiratory virus infections contribute substantially both to hospitalizations of young children, and to morbidity in immunocompromised patients such as those with hematological malignancies. Their rapid and accurate diagnosis is essential to patient management. To evaluate the prospective utility of Seeplex® DPO technology in respiratory virus diagnosis, a panel of 99 respiratory samples positive by real‐time RT‐PCR for one or more viruses was assayed by the Seegene Seeplex® RV12 system. As well as being able to detect all 10 viruses in the real‐time RT‐PCR system with the exception of enteroviruses, RV12 can also distinguish between the two subgroups of RSV and detect two subgroups of coronaviruses. Seven of the nine viruses in common with the RT‐PCR were detected reliably by RV12. Eleven samples RT‐PCR‐positive for Metapneumovirus and five samples positive for influenza B were not detected by RV12. Seegene developed a second‐generation system, RV15, which not only allowed detection of three additional viruses, but also addressed the potential problems with RV12 specificity. To address these concerns, 84 respiratory samples positive for a range of viruses by real‐time PCR were assayed with RV15. The results of this evaluation improved significantly upon those seen with RV12. The high throughput capabilities and potential lower technical requirements afforded by the Seeplex® system may offer an alternative to real‐time RT‐PCR systems. J. Med. Virol. 83:1469–1475, 2011. © 2011 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract A dengue‐3‐specific real‐time reverse transcriptase‐polymerase chain reaction (RT‐PCR) was developed using the novel __L__ight __U__pon e__X__tension (LUX™) fluorogenic technology. A labeled forward primer and a standard reverse primer that target a conserved region within the non‐struc
## Abstract One hundred forty‐nine specimens were tested in a LightCycler nested multiplex polymerase chain reaction (LCnmPCR) for Herpes simplex virus (HSV)1, HSV2, and VZV. Eighty‐one were from genitourinary medicine (GUM) patients and the other 68 specimens were from other patients with skin les
## Abstract To compare the specificity and sensitivity of a real‐time fluorescent RT‐PCR assay with conventional RT‐PCR, sera from 110 healthy blood donors, 120 patients with a clinical diagnosis of chronic hepatitis B, and 416 patients with non‐A‐C acute hepatitis, as well as serial dilutions of H
## Abstract This study compares herpes simplex virus (HSV) type‐specific loop‐mediated isothermal amplification (LAMP) with virus isolation and real‐time PCR. Genital tract specimens were obtained from 25 patients with genital lesions; two swab samples were collected from the vulva and cervix of ea
## Abstract A two‐step reverse transcriptase TaqMan™ duplex PCR (RT‐PCR) assay was developed using the ABI 7700 Sequence Detection System for the detection of enterovirus (EV) and parechovirus type 1 and 2 (PEV) RNA from samples of cerebrospinal fluid (CSF) and throat swabs. Using sequence‐specific