✦ Synopsis


Sebba (1987)
defined colloidal gas aphrons (CGA) as microbubbles stabilized by surfactant layers, which are created by stirring surfactant solutions at speeds greater than a critical value. A high shear impeller is used for stirring and critical values for the impeller speed must be exceeded to create these stable gas liquid dispersions (typically >5000 rpm). Although there have been no previous reports of direct protein recovery using CGA, it is likely that, with appropriate choice of surfactant, proteins should adsorb to these surfactant bubbles by means of electrostatic and/or hydrophobic interactions. This is the basis of this study, in which the use of CGA for protein recovery from aqueous solution is considered. A surfactant which has been characterized previously for generation of CGA was chosen (Jauregi et al., 1997), i.e., the anionic surfactant sodium bis-(2-ethyl hexyl) sulfosuccinate (AOT). Lysozyme, a wellcharacterized protein, was chosen as the protein to be recovered. Lysozyme was recovered successfully from aqueous solution using CGA generated from AOT. At optimum conditions, lysozyme recovery, enrichment ratio, and separation ratio were 95%, 19 and 302 respectively, with enzyme activity maintained. These results indicate the exciting potential of this technique. A wide range of process conditions including initial concentration of protein and surfactant, surfactant/protein molar ratio, pH, and ionic strength were considered.

High recoveries and enrichments were generally obtained at protein concentrations ΰ΄›0.41 mg/mL, and surfactant concentrations >0.11 mg/mL. However, at high ionic strength (0.29M) poor separation and recoveries were obtained at low protein concentrations (counterions diminishing electrostatic interactions between protein and aphrons at this condition). In general, (n s /n p ) a was determined to be between 10 and 16 for experiments in which high levels of recovery/separation parameters were found. For most conditions, protein precipitation was observed; however, this precipitate could be resolubilized without loss of enzyme activity.


πŸ“œ SIMILAR VOLUMES


Effect of air to solid ratio in the clar
✍ Mohd A. Hashim; Bhaskar Sen Gupta; Seetharam Vijaya Kumar; Roxane Lim; Song E. L πŸ“‚ Article πŸ“… 1998 πŸ› Wiley (John Wiley & Sons) 🌐 English βš– 328 KB πŸ‘ 1 views

A study on the clariÐcation of bakerÏs yeast suspension by Colloidal Gas Aphrons (CGA) employing a cationic surfactant, benzyl-dimethyl-hexadecylammonium chloride, is presented. The variables investigated were the CGA Γ‘owrate, air Γ‘owrate and the yeast concentration. A separation efficiency as high

A Novel, Q-PCR Based Approach to Measuri
✍ Min Zhang; Scott Lute; Lenore Norling; Connie Hong; Aurelia Safta; Deborah O'Con πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 422 KB

## Abstract Quantification of virus removal by the purification process during production is required for clinical use of biopharmaceuticals. The current validation approach for virus removal by chromatography steps typically involves time‐consuming spiking experiments with expensive model viruses