Abstract

The purpose of this study was to explore the effects of changes in Type I collagen on the viscoelasticity of bone. Bone coupons were heated at either 100 or 200 °C to induce the thermal denaturation of Type I collagen. Half of these specimens were rehydrated after heat treatment; the other half were tested in a dry condition. The degree of denatured collagen (DC%) was analyzed by a selective digestion technique with the use of α‐chymotrypsin. Isothermal (37 °C) and variable temperature tests (scans from 35 to 200 °C) were performed with the use of a dynamic mechanical analyzer to evaluate changes in bone viscoelastic properties as a function of collagen damage, specifically, changes in the loss factor (tan δ) and storage modulus (E′) were assessed. Significant collagen denaturation occurred only when bone was heated at 200 °C irrespective of the hydration condition. Also, DC% did not show a significant effect on tan δ. However, higher values of tan δ were observed in wet samples compared to dry specimens. The temperature‐scan tests revealed that the hydration condition, but not DC%, significantly affected the behavior of tan δ. However, E′ was not strongly influenced either by DC% or by water content. These results suggest that at a constant frequency the denaturation of collagen triple‐helical molecules may have few effects on the viscoelasticity of bone, but moisture may play a prominent role in determining this property. © 2001 Wiley Periodicals, Inc. J Biomed Mater Res (Appl Biomater) 63: 31–36, 2002


📜 SIMILAR VOLUMES


Characterization of acrylic bone cement
✍ Yang, Jen-Ming ;Li, Hui-Min ;Yang, Ming-Chien ;Shih, Chun-Hsiung 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 203 KB 👁 2 views

Dynamic mechanical analysis (DMA) was used to characterize the properties of acrylic bone cement with the addition of tricalcium phosphate (TCP), hydroxyethyl methacrylate (HEMA), and ethylene glycol dimethacrylate (EGDMA). The glass transition temperature of acrylic bone cement is ú100ЊC; the cemen

Dynamic mechanical and rheo-optical stud
✍ James C. W. Chien; E. P. Chang 📂 Article 📅 1972 🏛 Wiley (John Wiley & Sons) 🌐 English ⚖ 848 KB

## Abstract The frequency dependence of dynamic mechanical properties of rat tail tendon (RTT), enzyme‐solubilized collagen membranes (ESC), AKM‐23 dialysis membranes, and gelatin film have been measured at 110, 11, and 3.5 Hz from ‐ 160 to 220°C. RTT and AKM‐23 are devoid of a rubbery region; ther

Effects of end boundary conditions and s
✍ Dong, X. Neil ;Yeni, Yener N. ;Les, Clifford M. ;Fyhrie, David P. 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 208 KB 👁 1 views

## Abstract The viscoelastic properties of cancellous bone can be measured nondestructively in compression testing using a dynamic mechanical analyzer. In this study, we examined the effects of end boundary conditions and specimen geometry on the viscoelastic properties of cancellous bone measured

The dynamic mechanical, dielectric, and
✍ An-Lac Nguyen; Ban The Vu; Garth L. Wilkes 📂 Article 📅 1974 🏛 Wiley (John Wiley & Sons) 🌐 English ⚖ 909 KB

## Abstract The dielectric, dynamic mechanical, and melting (denaturation) behavior of reconstituted collagen has been investigated. Dynamic mechanical properties are reported for the range of temperature from −100 to 220°C. Dielectric properties are reported for the range of temperature from −120