𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Clinical experience with 13C MRS in vivo

✍ Scribed by Brian Ross; Alexander Lin; Kent Harris; Pratip Bhattacharya; Brian Schweinsburg


Publisher
John Wiley and Sons
Year
2003
Tongue
English
Weight
380 KB
Volume
16
Category
Article
ISSN
0952-3480

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

^13^C MRS was installed on a clinical scanner at 1.5 T in order to facilitate integrated MR examinations of human brain disorders. Using a simplified protocol, (1‐^13^C) glucose and/or (1‐^13^C) acetate were administered orally or by intravenous infusion. ^13^C spectra of diagnostic quality were acquired in more than 100 consecutive studies. Novel ^13^C neurochemical data contributed to the understanding of Alzheimer's, Canavan's, mitochondrial and hepatic encephalopathy, epilepsy and normal brain development. ^13^C MRS uncovered hitherto unknown disorders of NAA‐synthesis, glutamate neurotransmission, TCA‐cycle and glycolysis. Despite low inherent signal‐to‐noise, natural abundance ^13^C MRS showed diagnostic promise. ^13^C MRS is feasible in a clinical setting, at reasonable cost in neonates, children, adults and elderly patients. Copyright Β© 2003 John Wiley & Sons, Ltd.


πŸ“œ SIMILAR VOLUMES


Direct validation of in vivo localized 1
✍ Hongxia Lei; Florence Morgenthaler; Tianwen Yue; Rolf Gruetter πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 183 KB

## Abstract With the use of localized ^13^C MRS in conjunction with [1‐^13^C]‐D‐glucose infusion, it is possible to study brain glycogen metabolism in vivo. The purpose of this study was to validate in vivo ^13^C MRS measurements by comparing them with results from a standard biochemical assay. To

Heteronuclear Cross Polarization for Enh
✍ Adrianus J. van den Bergh; Hendrikus J. van den Boogert; Arend Heerschap πŸ“‚ Article πŸ“… 1998 πŸ› Elsevier Science 🌐 English βš– 318 KB

The potential of heteronuclear { 1 H-13 C} cross polarization was studied for optimization of the signal-to-noise ratio in in vivo 13 C MR spectroscopy at the clinical field strength of 1.5 T. Experiments on the human calf showed a significant chemical-shift selective signal enhancement on triglycer

Alternative 1-13C glucose infusion proto
✍ Angel Moreno; Stefan BlΓΌml; Jong-Hee Hwang; Brian D. Ross πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 237 KB

Clinical utility of (13)C MRS is limited by cost and long examination times. Three 1-(13)C glucose infusion protocols-a high-dose i.v., low-dose i.v., and oral administration of 1-(13)C glucose-were compared on a GE 1.5T MR scanner. Resolution and sensitivity were sufficient to identify (13)C glucos