✦ Synopsis


Abstract

Three‐dimensional (3D) MP‐RAGE (magnetization‐prepared rapid gradient‐echo) imaging was evaluated as a high‐resolution 3D T1‐weighted brain imaging technique for patients with suspected neurologic disease. Fourteen patients were studied. In five, 3D MP‐RAGE images were compared with 3D FLASH (fast low‐angle shot) images. Signal difference‐to‐noise ratios and T1 contrast were not statistically different for 3D MP‐RAGE images as opposed to 3D FLASH images. Advantages intrinsic to the application of 3D MP‐RAGE sequences include decreased imaging time and decreased motion artifact. With this technique, it is possible to perform a relatively motion‐insensitive, T1‐weighted screening brain study with voxel resolution of 1.0 × 1.4 × 2.0 mm or smaller, in an imaging time of 5.9 minutes or less‐permitting offline (poststudy) reconstruction of high‐resolution images in any desired plane.


📜 SIMILAR VOLUMES


Three-dimensional dynamic liver MR imagi
✍ Young Kon Kim; Chong Soo Kim; Hyo Sung Kwak; Jeong Min Lee 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 804 KB

## Abstract ## Purpose To assess the diagnostic performance of three‐dimensional dynamic liver imaging with sensitivity encoding (SENSE), including double arterial phase images and increased resolution, by comparing it to superparamagnetic iron oxide (SPIO)‐enhanced magnetic resonance (MR) imaging

A clinical comparison of rigid and infla
✍ Susan M. Noworolski; Jason C. Crane; Daniel B. Vigneron; John Kurhanewicz 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 707 KB

## Abstract ## Purpose To compare the data quality and ease of use of four endorectal‐coil probe setups for prostate MRI. ## Materials and Methods Four endorectal‐coil probe setups were compared: 1) air‐inflated probe; 2) perfluorocarbon (PFC)‐inflated probe; 3) rigid, smaller prototype coil; an

Comparison of three physiologically-base
✍ Daniel P. Barboriak; James R. MacFall; Benjamin L. Viglianti; Mark W. Dewhirst D 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 676 KB

## Abstract ## Purpose To compare the performance of three physiologically‐based pharmacokinetic (PBPK) models for predicting gadolinium contrast agent concentration‐time curves (Gd‐CTCs) obtained in superior sagittal sinus (SSS), cerebral cortex, and psoas muscle. ## Materials and Methods Three