Classification of different cola drinks by membrane inlet mass spectrometry (MIMS) combined with

different statistical computing methods is demonstrated. The spectra of cola drinks were measured directly using a single quadrupole mass spectrometer with a hollow fiber membrane inlet in standard MIMS and trap-and-release MIMS modes, and the spectra obtained were analyzed by principal component analysis and the mean pairwise difference method, and classified via the k-NN classifier. The multivariate calculations showed that cola drinks from different manufacturers can easily be differentiated from one another although the spectra of all drinks are usually very alike with minor differences in the abundances of major ion peaks in the range m/z 50-199. The classification of drinks is rapid as a spectrum of one sample can be obtained in a few minutes.


πŸ“œ SIMILAR VOLUMES


A non-linear asymmetric error function-b
✍ Raimo A. Ketola; Marja Ojala; Veikko Komppa; Tapio Kotiaho; Jouni JuujΓ€rvi; Jukk πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 104 KB πŸ‘ 2 views

A nonlinear asymmetric error function-based least mean square method (NALMS) for the deconvolution of identity and quantity of individual compounds based on the multicomponent mass spectra measured by membrane inlet mass spectrometry (MIMS) was developed and detailed testing results are presented. T

On-line biodegradation monitoring of nit
✍ Colin S Creaser; David GΓ³mez Lamarca; Luisa M Freitas dos Santos; Giuseppe LoBiu πŸ“‚ Article πŸ“… 2003 πŸ› Wiley (John Wiley & Sons) 🌐 English βš– 156 KB

## Abstract Membrane inlet mass spectrometry (MIMS) has been developed for the on‐line monitoring of compounds in a continuous stirred tank bioreactor (CSTB) used to simulate a wastewater treatment plant (WWTP). A mixture of four industrially relevant nitrogen‐containing volatile and semi‐volatile

Reaction of water at hot filament interf
✍ Henrik Ørsnes; Sandor Bohatka; Hans Degn πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 77 KB πŸ‘ 2 views

The measurement by membrane inlet mass spectrometry of gases dissolved in water is hampered by high and unstable background signals caused by residual gases whose origins have not been thoroughly investigated. We propose that significant amounts of gases are created by chemical reactions at the hot

An investigation of the aroma fraction o
✍ Donata Favretto; Giancarlo Grandis; Graziella Allegri; Pietro Traldi πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 151 KB πŸ‘ 2 views

Two analytical approaches have been applied to the characterization of the aroma fraction of five Italian wines, solid-phase micro-extraction coupled with gas chromatography, and membrane inlet mass spectrometry. The first approach resulted in highly specific and reproducible data and permitted the

High-resolution Mass Spectrometry and Ac
✍ Russell, David H.; Edmondson, Ricky D. πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 434 KB πŸ‘ 2 views

Fundamental concepts of high-resolution mass spectrometry as it relates to the issue of accurate mass measurements are presented. Important issues speciÐc to magnetic sector instruments, Fourier transform ion cyclotron resonance and time-of-Γ‘ight (TOF) methods are discussed. Recent high-resolution T