Abstract

The aim of this study was to investigate the fragmentation behavior induced by low‐energy collision‐induced dissociation (LE‐CID) of four selected antioxidants applied in lubricants, by two different types of ion trap mass spectrometers: a three‐dimensional ion trap (3D‐IT) and a linear IT (LIT) Orbitrap MS. Two sterically hindered phenols and two aromatic amines were selected as model compounds representing different antioxidant classes and were characterized by positive‐ion electrospray ionization (ESI) and LE‐CID. Various types of molecular ions (e.g. [M]^+•^, [M + H]^+^, [M + NH~4~]^+^ or [M + Na]^+^) were used as precursor ions generating a significant number of structurally relevant product ions. Furthermore, the phenolic compounds were analyzed by negative‐ion ESI. For both IT types applied for fragmentation, the antioxidants exhibited the same unusual LE‐CID behavior: (1) they formed stable radical product ions and (2) CC bond cleavages of aliphatic substituents were observed and their respective cleavage sites depended on the precursor ion selected. This fragmentation provided information on the type of structural isomer usually not obtainable for branched aliphatic substituents utilizing LE‐CID. Comparing the two instruments, the main benefit of applying the LIT‐Orbitrap was direct access to elemental composition of product ions enabling unambiguous interpretation of fragmentation trees not obtainable by the 3D‐IT device (e.g. loss of isobaric neutrals). It should be emphasized that the types of product ions formed do not depend on the type of IT analyzer applied. For characterizing degradation products of antioxidants, the LIT‐Orbitrap hybrid system, allowing the determination of accurate m/z values for product ions, is the method of choice. Copyright © 2011 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Structural characterizations of lipids A
✍ Alba Silipo; Cristina De Castro; Rosa Lanzetta; Antonio Molinaro; Michelangelo P 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 163 KB

## Abstract Here, a new ‘one pot’ and fast approach is described, based on electrospray ionization (ESI) of negative ions by using a hybrid linear ion trap/orbitrap mass spectrometer (LTQ/orbitrap) for MS and MS/MS analysis. By this method the distribution of the primary and secondary acyl residues

Study of ghost peaks resulting from spac
✍ Kocher, F.; Favre, A.; Gonnet, F.; Tabet, J.-C. 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 406 KB 👁 2 views

Ion trap improvements require some geometrical modiÐcations which can alter signiÐcantly the relative linear and non-linear Ðeld contributions. In this work, where the ion trap was interfaced with an electrospray source, it was shown that under particular ion trapping conditions due to space charge,

Collision-induced dissociation pathways
✍ Christer S. Ejsing; Thomas Moehring; Ute Bahr; Eva Duchoslav; Michael Karas; Kai 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 445 KB

## Abstract The yeast __Saccharomyces cerevisiae__ synthesizes three classes of sphingolipids: inositolphosphoceramides (IPCs), mannosyl‐inositolphosphoceramides (MIPCs), and mannosyl‐diinositolphosphoceramides (M(IP)~2~C). Tandem mass spectrometry of their molecular anions on a hybrid quadrupole t

A novel approach to perform metabolite s
✍ Wilson Z. Shou; Lisa Magis; Austin C. Li; Weng Naidong; Matthew S. Bryant 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 243 KB

## Abstract __In vitro__ metabolic stability experiments using microsomes or other liver preparations are important components in the discovery and lead‐optimization stages of compound selection in the pharmaceutical industry. Currently, liquid chromatography–tandem mass spectrometric (LC–MS/MS) su